Troubleshooting
Detection of errors
◆ If an error occurs during the operation, one or more LED flickers and the operation is stopped except the LED.
◆ If you re-operate the air conditioner, it operates normally at first, then detect an error again.
LED Display on the indoor unit
LED Display
Abnormal conditions
Power reset
Error of temperature sensor in indoor unit
(OPEN/SHORT)
Error of heat exchanger sensor in
indoor unit
Error of outdoor temperature sensor
Error of COND sensor
Error of DISCHARGE sensor
1. No communication for 2 minutes between
indoor unit and outdoor unit (communica-
tion error for more than 2 minutes)
2. Indoor unit receiving the communication
error from outdoor unit
3. Outdoor unit tracking 3 minute error
4. When sending the communication error
from outdoor unit the mismatching of the
communication numbers and installed
numbers after completion of tracking.
(communication error for more than
2 minutes)
Communication error between indoor units
●
On
Flickering X Off
◆ If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
◆ If you re-operate the air conditioner, it operates normally at first, then detect an error again.
20
E-
Indicators
Green
Red
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Operating
X
Displayed on appropriate indoor
X
unit which is operating
Displayed on appropriate indoor
X
unit which is operating
Displayed on appropriate indoor
X
unit which is operating
Displayed on outdoor unit
1. Error of indoor unit: Displayed
on the indoor unit regardless
of operation
2. Error of outdoor unit:
Displayed on the indoor unit
which is operating
X