Power Failure Connections - Panasonic KX-TDE100 Installation Manual

Hide thumbs Also See for KX-TDE100:
Table of Contents

Advertisement

3.12.1 Power Failure Connections

3.12 Power Failure Connections
3.12.1 Power Failure Connections
When the power supply to the PBX fails, power failure transfer (PFT) will switch from the current connection
to the Power Failure Connection. Refer to "13.1.11 Power Failure Transfer" in the Feature Manual for further
information.
Connection
Power Failure Connection connects a specific SLT and a CO line in the event of power failure. The following
analog CO line and extension cards can be used for Power Failure Connections:
Analog CO line cards: LCOT16 (4 PFT ports), LCOT8 (2 PFT ports)
Extension cards: MSLC16 (4 PFT ports), CSLC16 (4 PFT ports), SLC16 (4 PFT ports), DHLC8 (2 PFT
ports) and SLC8 (2 PFT ports)
To 1 analog CO line card, connect only 1 extension card.
Note
By programming the PBX, a CO line conversation established during power failure can be maintained even
when the power returns and the connection is switched back to the normal configuration from the Power
Failure Connection. However, if no special programming is performed, the connection will be dropped when
power returns.
CO Line Card
(e.g., LCOT8)
Accessories and User-supplied Items
Accessories (included): none
User-supplied (not included): RJ11 connectors
138
Installation Manual
RJ11
R2
T2
R1
T1
T1
R1
T2
R2
To CO line
To SLT
Extension Card
(e.g., SLC8)
Document Version 2010-08

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pure ip-pbxKx-tde200

Table of Contents