3.8.3 Digital EXtra Device Port (Digital XDP) Connection
A DPT can be connected to another DPT on the Digital XDP connection. In addition, if the DPT is connected
to a DHLC8 card, it can also have an SLT connected in Parallel mode or XDP mode.
Note
•
Both DPTs must be KX-DT300/KX-T7600 series DPTs (except KX-T7640). Note that the KX-T7667
can only be connected as a slave DPT.
•
Bluetooth
Modules or USB Modules must not be connected to DPTs in the Digital XDP connection.
®
•
Parallel mode or XDP mode can be selected through system programming.
•
If XDP mode is enabled through system programming, parallel connection is not possible. Refer to
"13.1.2 Paralleled Telephone" and "5.1.7 Extension Port Configuration" in the Feature Manual for
further information.
With KX-DT300 Series DPT
Using a Modular T-Adaptor
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
4-conductor wiring cord
Connect pins "D1" and
"D2".
Back View of DPTs
TO TEL
TO MAIN UNIT
/ PABX
Document Version 2010-08
Modular
T-Adaptor
4-conductor wiring cord
Connect pins "D1" and "D2".
Master DPT
Cable
Maximum Distance
26 AWG: 30 m (98 ft)
24 AWG: 50 m (164 ft)
22 AWG: 60 m (196 ft)
CAT 5:
50 m (164 ft)
Master DPT
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
3.8.3 Digital EXtra Device Port (Digital XDP) Connection
2-conductor wiring cord
Connect pins "T" and "R".
SLT
Slave DPT
TO MAIN UNIT
Slave DPT
/ PABX
Installation Manual