SECTION 5 CIRCUIT ADJUSTMENTS 5-1. ADJUSTMENTS WITH COMMANDER Service adjustments are made with the RM-869 that comes with 1, 4 this unit. Raise/lower the service item number 3, 6 Raise/lower the data [MUTING] Writes Entering service mode Executes the writing With the unit on standby ↓...
5-2. ADJUSTMENT METHOD Item Number 08 Use the same method for Items Number 00-41. Use 1 and 4 to This explanation uses V-SHIFT as an example. select the adjustment item, use 3 and 6 to adjust, write with 1. Select 08 V-SHIFT with the 1 and 4 buttons. , then execute the write with -.
Page 4
Adjustment Item Table Item Initial Note for Different Data Standard Data Function Device Item Data 50/60Hz/RGB 50/RGB 60 2C/33/31/38 H Shift 50/60Hz/RGB 50/RGB 60 35/35/35/35 H Size 50/60Hz 25/25 Pin Amplitude 50/60Hz 10/0C Corner Pin 50/60Hz 20/2D Tilt 50/60Hz 1F/1F V Slope 50/60Hz 1C/1B...
Page 5
Item Initial Note for Different Standard Data Function Device Item Data Data OSD H Position D/K Stereo enable/disable Muting on/off at No Sync Bright ABL Switch SECAM Trap active/inactive FBT L/S C/M strict/plain 28 (2199) 2F (J21) Optional Flags 0 (see below) Optional Flags 1 (see below) 24 (2199) 04 (J21)