5-3. RAS-13UKP-ES2 / RAS-13UA-ES2

RAS-13UKP-AS2 / RAS-13UA-AS2

Cooling
0.39m
(Connecting pipe)
∅12.7
O.D.:12.7mm
P
Packed valve
(∅12.7)
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Indoor unit
Heat exchanger
Cross flow fan
PA150X2T-4FM1
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
pipe T1 (°C)
0.90
1.10
0.70
– 17 –
FILE NO. SVM-03001
T1
Packed valve
(∅6.35)
Capillary tube
∅1.5x500S
Refrigerant
R410A : 0.97 kg.
Mark(
)means check points of Gas Leak.
Fan speed
(indoor)
9.0
High
13.0
High
2.0
Low
0.49m
(Connecting pipe)
∅6.35
O.D.:6.35mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15