Installing the Passport 8002PS
DC Power Supply
Part No. 207314-B
April 2000
4401 Great America Parkway
Santa Clara, CA 95054

Advertisement

Table of Contents
loading

Summary of Contents for Nortel Passport 8002PS

  • Page 1 Installing the Passport 8002PS DC Power Supply Part No. 207314-B April 2000 4401 Great America Parkway Santa Clara, CA 95054...
  • Page 2 In the interest of improving internal design, operational function, and/or reliability, Nortel Networks NA Inc. reserves the right to make changes to the products described in this document without notice. Nortel Networks NA Inc. does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
  • Page 3 Canadian Department of Communications Radio Interference Regulations This digital apparatus (Passport 8002PS DC Power Supply) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
  • Page 5: About This Guide

    Instructions for preparing cables to connect to the power supply • Operational notes about the power supply • Instructions for installing a Passport 8002PS DC Power Supply in an unoccupied bay of a Passport 8000 Series Chassis (page • Instructions for replacing an installed power supply in a Passport 8000 Series Chassis •...
  • Page 6: Preparing Cables

    Required tools: Crimping tool for crimping lugs onto cables; heat gun Nortel Networks does not supply the cables for connecting the Passport 8002PS DC Power Supply to the DC input power source. You can therefore select cables that comply with the electrical code of the country where you intend to use the DC power supply.
  • Page 7: Operational Notes

    When you first install a Passport 8000 Series Chassis that requires two power supplies (nonredundant configuration), you must turn on both power supply units within 2 seconds of each other. If you wait longer to turn on the second power supply, both power supplies will shut down. To correct this condition, turn off both power supplies, wait at least 30 seconds, and then turn on both power supplies again within 2 seconds.
  • Page 8 Leave the terminal block at the side of the power supply exposed. Note: If you are installing a power supply in a new chassis, be sure to remove the bag of moisture-absorbing material from the middle power supply bay. Warning: Make sure the DC power source is off or disconnected on the remote end before you connect the terminal leads to the power supply.
  • Page 9 Turn the power supply switch to the on position. Firmly slide the power supply all the way into the bay and tighten the retaining screws. Turn the DC input power source on, or reset the power source circuit breaker, to provide power to the power supply.
  • Page 10: Removing A Power Supply

    Removing a Power Supply Required tools: Phillips screwdriver, 7/16-inch wrench In a chassis with a redundant power supply configuration, you can replace or install a power supply without powering down the chassis. Turn off the power switch on the power supply you are replacing.
  • Page 11 9431FA Lift the extractor lever to disconnect the power supply from the backplane connector. Slide the power supply partway out of the chassis. 9427EB Disconnect the grounding cable from the ground lug on the power supply.
  • Page 12: Specifications

    Slide the power supply all the way out of the chassis, and set it aside. Install a replacement power supply following the instructions earlier in this guide. If you are not installing another power supply in this bay, install a filler panel over the opening.