Installation Instructions - Hotsy 981SS Operating Instructions And Parts Manual

Gas-fired series
Hide thumbs Also See for 981SS:
Table of Contents

Advertisement

Gas Valve
The ideal incoming gas pressure is 11 w.c.i. (water col-
umn inches) minimum 6 w.c.i., maximum 14 w.c.i. or 1/
2 psig. The correct operating manifold pressure for natu-
ral gas is 3.5 w.c.i. The operating manifold pressure for
propane gas is 11 w.c.i. The gas valve pressure regula-
tor can be adjusted between 3 and 4 w.c.i. natural gas
or 6 and 11 w.c.i.for propane.
The gas pressure coming out of the regulator and going
to the burner ring has been factory set. You should not
readjust the burner ring gas pressure. If you replace
your gas valve, you will need to adjust the new valve.
Refer to your machine's specification plate for the
correct pressure setting. Follow the installation and ad-
justment instructions provided with your replacement
valve.
12

INSTALLATION INSTRUCTIONS

97-6574 • HOTSY 900-1400 GAS FIRED • REV. 10/05
Electrical
WARNING: Make sure all switches and controls
are in the OFF position prior to connecting electrical
supply.
WARNING: DO NOT stand in water while connecting
and disconnecting electrical supply.
WARNING: Always disconnect power before servic-
ing your pressure washer.
IMPORTANT: Consult local building codes for exact
electrical requirements. Licensed contractors may be
required.
IMPORTANT: All wiring must be of proper voltage and
amperage rating and conform to applicable codes.
IMPORTANT: This machine must be electrically
grounded. LA MACHINE DOIT ÊTRE MISE À LA
TERRE.
Grounding Instructions: Make sure all switches and
controls are in the OFF position prior to connecting elec-
trical supply. Do not stand in water while connecting
and disconnecting electrical supply. If it should mal-
function or break down, grounding provides a path of
least resistance for electric current to reduce the risk of
electric shock. The product must be connected to an
appropriate power source that is properly installed and
grounded in accordance with all local codes and ordi-
nances.
DANGER: Improper connection of the equipment
grounding conductor can result in a risk of electro-
cution. Check with a qualified electrician or service
personnel if you are in doubt as to whether the
outlet is properly grounded.
Extension Cords: Do not use extention cords with this
equipment.
WARNING: To reduce the risk of electrocution, keep
all connections dry and off the ground.