CU-E21PKE
230V
30 °C
Indoor
wet bulb
TC
SHC
17.0 °C
6.25
4.74
19.0 °C
19.5 °C
6.86
4.96
22.0 °C
7.48
5.14
CU-E24PKE
230V
30 °C
Indoor
wet bulb
TC
SHC
17.0 °C
6.75
5.11
19.0 °C
19.5 °C
7.41
5.35
22.0 °C
8.07
5.55
CU-E28PKE
230V
30 °C
Indoor
wet bulb
TC
SHC
17.0 °C
7.59
5.75
19.0 °C
19.5 °C
8.33
6.02
22.0 °C
9.08
6.25
TC
- Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP
- Input Power (kW)
Indoor 27°C/19°C
Outdoor 35°C/24°C
35 °C
IP
TC
SHC
2.00
5.84
4.54
6.30
2.03
6.41
4.77
2.07
6.99
4.95
35 °C
IP
TC
SHC
1.91
6.30
4.90
6.80
1.94
6.92
5.14
1.98
7.54
5.34
35 °C
IP
TC
SHC
2.31
7.09
5.52
7.65
2.35
7.79
5.79
2.39
8.48
6.01
Outdoor Temperature
40 °C
IP
TC
SHC
2.15
5.43
4.37
2.18
2.19
5.97
4.59
2.23
6.50
4.77
Outdoor Temperature
40 °C
IP
TC
SHC
2.05
5.86
4.71
2.08
2.09
6.44
4.95
2.13
7.02
5.15
Outdoor Temperature
40 °C
IP
TC
SHC
2.48
6.59
5.30
2.52
2.53
7.24
5.57
2.58
7.89
5.79
186
46 °C
IP
TC
SHC
2.30
4.94
4.15
2.34
5.42
4.37
2.38
5.91
4.55
46 °C
IP
TC
SHC
2.19
5.33
4.48
2.23
5.85
4.71
2.27
6.38
4.91
46 °C
IP
TC
SHC
2.66
6.00
5.04
2.71
6.59
5.30
2.75
7.18
5.53
IP
2.548
2.52
2.57
IP
2.36
2.41
2.45
IP
2.87
2.92
2.97