Repair Quality Assurance - Canon A-1 Repair Manual

Hide thumbs Also See for A-1:
Table of Contents

Advertisement

used in the correct camera.
Lubrication is also dif-
ferent
from
the
~-l.
6.7
The A-I
is
a system camera.
Interchangeability and correct
operation
with
accessories must
be
considered when
repairing it.
6.8
The viewfinder screen is interchangeable by service.
When it is changed, always chec!, the infinity focus and
exposure.
6.9
Much information is presented in digital form in the
viewfinder, and it is different for each mode of operation.
If the imformation presented in all different modes is
not thoroughly understood, answering inquiries, especially
over the telephone, is difficult and may lead to more
confusion.
6.10
Repair Quality Assurance
(1)
Shutter Speed is
adjusted
by
varyi~g
the count start
(CTST) timing with variable resistor VRT.
(Shutter Speed Tester is necessary)
(2)
Flange Focal Distance is adjusted to 42.14 mm using
the Glass gage and
me
asuring at the four corners.
(3)
The
"finder
back" is
adjusted
to 42.03 mm using the
standard lens.
(4)
Exposure accuracy is adjusted by the SPC output using
the Bus Checker tool to check the I Bus.
It is then
confirmed using the EE Camera Tester.
If exposure
accuracy is not wi
t
h
i
n the proper limits, check the
diaphragm
and
MGl
release
operation with the oscillo-
scope.
(If the AE Evaluation Standard Lens is
available, check the diaphragm operation with it,)
(5)
Check the 0 BUS output from the CPU to the decoder
driver against the
a
ctual display
in the viewfinder
using the Bus
Checke
r tool.
(I Bus inputs to the CPU
must be correct as a
precondit~on.)
(6)
Inputs to CPU are checked with the Bus Checker tool.
(7)
To adjust the ASA (SV) brush, the SV Check Bit tool
is used.
The top cover provides the positioning pin
for the SV Check Bit tool.