Alert! Previous system fan failure.
Alert! Previous temperature failure at
Processor 0.
Alert! Previous temperature failure at
Processor 1.
Alert! Previous voltage failure.
Alert! Processor 0 failed Build-In Self
Test (BIST).
Alert! Processor 1 failed Build-In Self
Test (BIST).
Alert! Processor Cache Size Mismatch.
Alert! Processor Speed Mismatch. Install
like processors or one processor and a
termination card.
Alert! Processor Type Mismatch. Install
like processors or one processor and a
termination card.
Alert! Single-bit memory error previously
detected in XXXXh.
Alert! System battery voltage is low.
Alert! System fan not detected.
Alert! Uncorrectable memory error
previously detected in XXXXh.
Alert! Unsupported high power AGP Pro
video adapter detected. System halted!
Attachment failed to respond
Bad command or file name
Bad error-correction code(ECC) on disk
read
Controller has failed
Data error
Decreasing available memory
System fan failed or was blocked
during the previous operating
session.
Processor 0 exceeded its
recommended operating
temperature range during the
previous operating session.
Processor 1 exceeded its
recommended operating
temperature range during the
previous operating session.
System voltage exceeded or fell
below acceptable thresholds.
Processor 0 is faulty or improperly
seated.
Processor 1 is faulty or improperly
seated.
Two processors with different L2
cache sizes are installed.
Two processors that are not of the
same speed are installed.
Two processors that are not of the
same type are installed.
Faulty or improperly seated RIMMs
or defective system board.
System battery is providing
inadequate voltage.
No system fan is installed; system
fan has failed; system fan is not
connected to the system board.
RIMMs are faulty or improperly
seated, or system board is
defective.
A high-power AGP Pro110 video
adapter is installed in the desktop
chassis.
The diskette drive or hard-disk drive
controller cannot send data to the
associated drive.
The command you entered does not
exist or is not in the pathname you
specified.
The diskette drive or hard-disk drive
controller detected an uncorrectable
read error.
The hard-disk drive or the
associated controller is defective.
The diskette or hard-disk drive
cannot read the data.
One or more Rambus in-line
memory modules (RIMMs) may be
Ensure that an operational system fan is
installed, connected to the system board,
and that chassis ventilation slots are not
blocked.
Ensure that an operational processor fan
is installed, connected to the system
board, and that chassis ventilation slots
are not blocked.
Ensure that an operational processor fan
is installed, connected to the system
board, and that chassis ventilation slots
are not blocked.
See
"Troubleshooting the System
Reseat or replace processor 0.
Reseat or replace processor 1.
Replace one of the processors so that the
L2 cache sizes match, or install a
termination card in PROC_1 slot on
system board.
Replace one of the processors so that the
speeds match, or install a termination
card in PROC_1 slot on system board.
Replace one of the processors so that the
types match, or install a termination card
in PROC_1 slot on system board.
See
"Troubleshooting System
Memory."
See
"Troubleshooting the System
See
"Troubleshooting the
Battery."
Ensure that an operational system fan is
installed and connected to the system
board.
See
"Troubleshooting System
Memory."
See
"Troubleshooting the System
Replace the AGP Pro110 video adapter
with an AGP Pro50 video adapter.
See
"Troubleshooting
Drives."
Make sure you have spelled the command
correctly, placed spaces in the proper
location, and used the correct pathname.
See
"Troubleshooting
Drives."
See
"Troubleshooting
Drives."
Run the ScanDisk utility in the Microsoft® 
Windows® operating system to check the
file structure of the diskette or hard-disk
drive. See your operating system
documentation for more information.
If you are using another operating system,
run the appropriate utility to check the file
structure of the diskette or hard-disk drive.
See your operating system
documentation.
See
"Troubleshooting System
Memory."
Board."