Toshiba RAS-07SKHP-E Service Manual page 51

Table of Contents

Advertisement

9-5-2. Power can not be turned on after replacing indoor P.C. board
<Checking Procedure>
Connect the AC
Power supply
Does the OPERATION
lamp blink?
YES
RAS-07SKHP-E, RAS-10SKHP-E
1 2
3
4
Indoor Terminal Block
NO
Is it wired as shown
in Figure below?
Green & yellow
L N
Supply AC 220 ~ 240 V
50 / 60 Hz
NO
YES
− 50 −
FILE NO. SVM-07023
Return the wiring of the
power relay is returned to
the normal procedure.
To the paragraph of
"No Power turns on".
CN31
RY01
4
3
T02