8-5-4. Wiring connection
1. Remove the valve cover from the outdoor unit.
2. Connect the connecting cable to the terminal as
identified with their respective matched numbers on
the terminal block of indoor and outdoor unit.
3. When connecting the connecting cable to the
outdoor unit terminal, make a loop as shown in the
installation diagram of indoor and outdoor unit, to
prevent water coming in the outdoor unit.
4. Insulate the unused cords (conductors) from any
water coming in the outdoor unit. Proceed them so
that they do not touch any electrical or metal parts.
<Stripping length of connecting cable>
For RAS-07S2AH-E
Terminal block
75 mm
10 mm
Earth line
Terminal
screw
10 mm
Connecting
65 mm
cable
Fig. 8-5-9
For RAS-10S2AH-E
Terminal block
100 mm
Earth line
10 mm
Terminal
screw
10 mm
Connecting
50 mm
cable
Fig. 8-5-10
CAUTION
CAUTION
• Wrong wiring connection may cause some
electrical parts burn out.
• Be sure to comply with local codes on running
the wire from indoor unit to outdoor unit (size of
wire and wiring method etc.)
• Every wire must be connected firmly.
NOTE
• Wire type : H07 RN-F or 245 IEC66 (2.0 mm
Screw
Earth
line
Cord clamp
Screw
Earth
line
Cord clamp
2
or more)
− 43 −
FILE NO. SVM-07023
8-6. How to Set Remote Contr
A or B
When operating one indoor unit in a situation where
two indoor units have been installed in the same
room or nearby rooms, this operation prevents the
remote controller signal from being received
simultaneously by both units, thus preventing both
units from operating.
·
The indoor unit on which the remote controller
selection has been set to B receives the signal
of the remote controller also set to B.
(At the factory the remote controller selection is
set to A on all the indoor units. There is no
A setting display.)
·
The remote control signal is not recived when the
indoor unit setting is different from the remote
control one.
Remote Control B Setup
1) Press RESET button on the indoor unit to turn
the air conditioner ON.
2) Point the remote control at the indoor unit.
·
3) Push and hold CHK button on the Remote
Control by the tip of the pencil. "00" will be shown
on the display.
·
4) Press MODE during pushing CHK . "B" will
show on the display and "00" will disappear and
the air conditioner will turn OFF. The Remote
Control B is memorized.
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
"B" Display
"00" Display
ONE-TOUCH
QUIET
SWING
TIMER
ol Selector
·
PRESET
FAN
MODE
COMFORT
SLEEP
FIX
Hi-POWER
ECO
CLR
ON
OFF
SLEEP
SET
Fig. 8-6-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10skhp-eRas-07s2ah-eRas-10s2ah-e

Table of Contents