Minimum Clearances To Combustibles - Regency PTO30CFT-2 Owners & Installation Manual

Plateau series outdoor decorative gas appliances
Hide thumbs Also See for PTO30CFT-2:
Table of Contents

Advertisement

The clearances listed below are Minimum distances unless otherwise stated:
A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
decorative gas appliance be installed only in accordance with these instructions.
Clearance:
A: Back wall
B: Sidewall
C: Ceiling
D
D
E: Alcove Width
F: Alcove Depth
Notes:

MINIMUM CLEARANCES TO COMBUSTIBLES

if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this decorative gas
appliance be installed only in accordance with these instructions.
Plateau® Series Clearance Requirements
Dimension
17" (432mm)
17" (432mm)
45" (1143mm)
: Floor
1
: Floor
2
84"(2134mm)
60" (1524mm)
A
WARNING
Fire hazard is an extreme risk
Burner to back wall
Burner to sidewall
Burner to Ceiling
0"
When using supplied leveling legs or optional casters.
1"(25mm)
Unit Base to Floor
Wall to Wall (Minimum)
Front to Back Wall (Maximum)
0"
No Hearth Required
C
B
D
E
F
Alcove
installation
Measured From:
Regency Plateau
®
Series Outdoor Gas Fireplace
|