8 Installation
Supplied By www.heating spares.co Tel. 0161 620 6677

4.6. Dis-assemble The Fire

a) Remove the dressguard
b) Carefully remove the radiant pack from the front of the
fire.
c) Pull off the control knob.
d) Remove the outer case by removing the two case
securing screws accessible through the lower holes in
the side panels. See Fig. 11.
e) Draw the case forward at the bottom and lift off.
f)
Screw the flue spigot and spigot restrictor, (if required) to
the back panel using thescrews above and below the
flue aperture.
Note:
The flue spigot may be extended to a maximum
total length of 160mm, measured from the back of
the fire if needed, for any of the following reasons:
1. If the fire is fitted to a recessed fireplace and the existing
flue spigot does not enter the closure plate by at least
25mm.
2. If an extension of the flue spigot backwards into a deep
fireplace would help clearance of products.
Note:
In all cases the spigot or its extension should pass at
least 25mm through the closure plate. See Fig 12.
g) If the fire is to be wall mounted the two leg
assemblies should be removed.

4.7. Mounting The Fire

a) Offer the fire chassis to the closure plate and enter the
flue spigot into its aperture in the close plate.
b) Make sure the fire is level and mark the four mounting
holes, then remove the chassis and place to one side.
c) Drill and plug the wall (using No. 8 wall plugs).
d) Partially screw in the two top screws (using 38mm x
No.10 screws). Make sure they are firm enough in the
wall to support the fire.
d) Hang the fire on the two top screws and swing the flue
spigot through the closure plate aperture.
e) Fit the bottom screws and tighten all four screws up
securing the fire chassis to the wall.

4.8. Prepare The Fire Connection

The appliance shall be connected with rigid or semi-rigid
tubing.
The gas inlet is at the bottom rear centre of the appliance
under the convector box. An RC1A (¼inch BSP Internal
Taper) union elbow is provided and a suitable supply can be
directed through 3600 to the position required.