Potterton Hallmark Installation & Service Instructions Manual
Potterton Hallmark Installation & Service Instructions Manual

Potterton Hallmark Installation & Service Instructions Manual

Radiant convector gas fire

Advertisement

G.C. NO. 32 230 32
Installation & Service Instructions
Hallmark
Radiant Convector Gas Fire
THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1994.
"In your own interest, and that of safety, it is law that all gas appliances are installed by competent persons, in accordance
with the above regulations. Failure to install appliances correctly could lead to prosecution."
Installation must be in accordance with these Installation and Service Instructions and the rules in force.
The polythene bags used for packaging are a potential hazard to babies and young children and
MUST BE DISPOSED OF IMMEDIATELY.
LEAVE THESE INSTRUCTIONS WITH THE USER FOR USE ON FUTURE CALLS
For Use With Natural Gas
IMPORTANT
PLEASE READ THIS BOOK
(G20) Only At 20mbar
BEFORE INSTALLING
For Use in GB
OPERATING OR SERVICING
THIS APPLIANCE
Supplied By www.heating spares.co Tel. 0161 620 6677

Advertisement

Table of Contents
loading

Summary of Contents for Potterton Hallmark

  • Page 1 G.C. NO. 32 230 32 Installation & Service Instructions Hallmark Radiant Convector Gas Fire THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1994. “In your own interest, and that of safety, it is law that all gas appliances are installed by competent persons, in accordance with the above regulations.
  • Page 2: Table Of Contents

    Contents - Page 2 TECHNICAL DATA..............................3 GENERAL................................4 INSTALLATION REQUIREMENTS ......................... 4 3.1 Fire location ............................... 4 3.2 Check The Chimney ............................4 3.3 Combustible Wall Cladding..........................5 3.4 Fireplace Opening ............................. 5 3.5 Fire Surround & Shelves............................ 5 3.6 Spigot &...
  • Page 3: Technical Data

    1. Technical Data - Page 3 Input (Full On) 5.42 kW 19.51 MJ/h (18,500 Btu/h) Gross Output (Full On) 3.25 kW 11.70 MJ/h (11,100 Btu/h) (under typical flue pull conditions) Input (Min.Setting) 1.67 kW 6.01 MJ/h (5,700) Btu/h) Gross Injectors Bray Cat 28 size 195 (upper and lower) Burner Bray No.
  • Page 4: General

    2. General - Page 3 The Hallmark is an Radiant Convector gas fire, it is lit by a piezo spark igniter so batteries or electricity are not required. The radiant heat is created by the use of ceramic radiants mounted centrally below the convector box.
  • Page 5: Combustible Wall Cladding

    3. Installation Requirements - Page 5 3.3. Combustible Wall If the wall against which the fire is to be installed has combustible cladding or surround, the following conditions must be met: Note: Certain types of wall coverings may be prone to discolouration.
  • Page 6: Spigot & Spigot Extension

    3. Installation Requirements - Page 6 3.6. Spigot & Spigot Extension The flue spigot or spigot extension MUST pass through the closure plate by at least 25mm and have a minimum clearance of 50mm between its opening & the nearest obstruction.
  • Page 7: Closure Plate - Wall Mounted

    4. Installation - Page 7 4.3. Closure Plate – Wall Mounted Note: See Combustible Wall Cladding-page 5. This fire is not suitable for use on combustible walls. a) When wall mounted, the bottom of the fire must be at least 150mm from the floor or top surface of any combustible material, e.g.
  • Page 8: Dis-Assemble The Fire

    4. Installation - Page 8 4.6. Dis-assemble The Fire a) Remove the dressguard b) Carefully remove the radiant pack from the front of the fire. c) Pull off the control knob. d) Remove the outer case by removing the two case securing screws accessible through the lower holes in the side panels.
  • Page 9: Gas Connection

    4. Installation - Page 9 4.8. Prepare The Fire Connection Cont. IMPORTANT: In all Installations, a means of isolating the main gas supply must be fitted close to the fire, so the fire can easily be removed for servicing. When the fire is in position, the air relief opening is covered by a deflector plate fastened to the back of the fire.
  • Page 10: Test For Spillage

    5. Check Gas Pressure & Operation Of Fire - Page 10 5.0. Check Gas Pressure & Operation Of Fire - Cont. Once the burner is lit, the fire should remain on the its maximum setting 6 . g) Check the gas pressure, it should be:- 18.9mbar ±...
  • Page 11: Complete The Installation

    7. Complete The Installation a) Remove the control knob. Before re-fitting the outer case, show the customer the data badge and advise them to write the serial number in the space provided in the Instructions For Use - Page 6. b) Make sure the large flat washer between the fire chassis and the outer casing at the top of the control rod is in position.
  • Page 12: Servicing & Replacement Of Parts

    9. Servicing & Replacement of Parts # When servicing the fire, always remove dust and debris from the burner and fire interior. # We recommend that the complete fire is removed from the fireplace opening and the following steps performed:- Clear the opening of dust and debris.
  • Page 13: Burner And Electrode

    9. Servicing & Replacement of Parts - Page 13 9.2. Burner and Electrode 9.2.1 Electrode a) Perform General Access - 9.1. a) Remove the electrode lead. b) Disconnect the Gas supply union from the tap. b) Remove the nut and washer securing the electrode to the burner.
  • Page 14: Gas Tap, Piezo And Injectors

    9. Servicing & Replacement of Parts - Page 14 9.3. Gas Tap, Piezo And Injector a) Perform General Access -9.1. b) Remove the split pin connecting piezo to the control rod. c) Disconnect the union nut securing the gas pipe to the tap.
  • Page 15: Shortlistofspares

    10. Short List Of Spares G.C. Description Makers Part No 382 594 Electrode - APCO 7854 900/9446 145 845 Electrode Lead 900/9393 386 861 Control Tap Assembly (Concentric JC/A/91 5). 904/1044 Includes Key No. 30 398 493 Injector - Bray Cat.28 Size 195 900/705 397 730 Piezo Generator - Concentric No.

Table of Contents