G.C. NO. 32 230 32 Installation & Service Instructions Hallmark Radiant Convector Gas Fire THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1994. “In your own interest, and that of safety, it is law that all gas appliances are installed by competent persons, in accordance with the above regulations.
2. General - Page 3 The Hallmark is an Radiant Convector gas fire, it is lit by a piezo spark igniter so batteries or electricity are not required. The radiant heat is created by the use of ceramic radiants mounted centrally below the convector box.
3. Installation Requirements - Page 5 3.3. Combustible Wall If the wall against which the fire is to be installed has combustible cladding or surround, the following conditions must be met: Note: Certain types of wall coverings may be prone to discolouration.
3. Installation Requirements - Page 6 3.6. Spigot & Spigot Extension The flue spigot or spigot extension MUST pass through the closure plate by at least 25mm and have a minimum clearance of 50mm between its opening & the nearest obstruction.
4. Installation - Page 7 4.3. Closure Plate – Wall Mounted Note: See Combustible Wall Cladding-page 5. This fire is not suitable for use on combustible walls. a) When wall mounted, the bottom of the fire must be at least 150mm from the floor or top surface of any combustible material, e.g.
4. Installation - Page 8 4.6. Dis-assemble The Fire a) Remove the dressguard b) Carefully remove the radiant pack from the front of the fire. c) Pull off the control knob. d) Remove the outer case by removing the two case securing screws accessible through the lower holes in the side panels.
4. Installation - Page 9 4.8. Prepare The Fire Connection Cont. IMPORTANT: In all Installations, a means of isolating the main gas supply must be fitted close to the fire, so the fire can easily be removed for servicing. When the fire is in position, the air relief opening is covered by a deflector plate fastened to the back of the fire.
5. Check Gas Pressure & Operation Of Fire - Page 10 5.0. Check Gas Pressure & Operation Of Fire - Cont. Once the burner is lit, the fire should remain on the its maximum setting 6 . g) Check the gas pressure, it should be:- 18.9mbar ±...
7. Complete The Installation a) Remove the control knob. Before re-fitting the outer case, show the customer the data badge and advise them to write the serial number in the space provided in the Instructions For Use - Page 6. b) Make sure the large flat washer between the fire chassis and the outer casing at the top of the control rod is in position.
9. Servicing & Replacement of Parts # When servicing the fire, always remove dust and debris from the burner and fire interior. # We recommend that the complete fire is removed from the fireplace opening and the following steps performed:- Clear the opening of dust and debris.
9. Servicing & Replacement of Parts - Page 13 9.2. Burner and Electrode 9.2.1 Electrode a) Perform General Access - 9.1. a) Remove the electrode lead. b) Disconnect the Gas supply union from the tap. b) Remove the nut and washer securing the electrode to the burner.
9. Servicing & Replacement of Parts - Page 14 9.3. Gas Tap, Piezo And Injector a) Perform General Access -9.1. b) Remove the split pin connecting piezo to the control rod. c) Disconnect the union nut securing the gas pipe to the tap.