• CONTROL BOARD IC801 µPD784216AGF519-3BA (SYSTEM CONTROLLER)
Pin No.
Pin Name
1
TU-CE
2
TU-DATA
3
TU-CLK
4
TU-COUNT
5
TU-MUTE
6
SIMUKE1
7
SIMUKE2
8
TEST-B
9
VDD
10
TEST-A
11
EPROM-SCL
12
EPROM-SDA
13 to18
N.C
19
LCD-RESET
20
LCD-RS
21
LCD-E
22
TEST/VPP
23
N.C
24
VM-CONT
25
CD-ON
26
LOAD
27
TU-ON
28
MP3-LED
29 to 36
DB0 to DB7
37
VDD
38
X2
39
X1
40
VSS
41
XT2
42
XT1
43
RESET
44
FM/AM-SHIFT
45
N.C
46
PWR-KEY
47
CD-DOOR
48
N.C
49
MP3-INTB
50
CD-WRQ
51
AVDD
52
AVREF0
53
KEY2
54
KEY1
55
VH
56
REG-CHK
57
VM
I/O
Description
O
PLL chip enable signal output terminal
O
PLL serial data output terminal
O
PLL serial data transfer clock signal output terminal
I
PLL serial count data input terminal
O
Tuner muting on/off control signal output terminal "L": active
I
Destination setting terminall Fixed at "L" in this set
I
Destination setting terminall Fixed at "L" in this set
O
Not used
Power supply terminal (+3.2V)
I
CD automatic adjustment value check mode setting terminal Normally fixed at "H"
O
Serial clock signal output terminal to the EEPROM
I/O
Two-way serial data bus with the EEPROM
O
Not used
O
LCD system reset signal output terminal "L": reset
O
LCD drive signal output terminal
O
LCD drive signal output terminal
I
Not used
O
Not used
O
Middle voltage (+4.5V) detection signal output for battery check
O
CD power on/off control signal output terminal "L": CD on
O
Load control signal output for battery level check
O
Tuner power on/off control signal output terminal "L": tuner on
O
MP3 LED drive signal output terminal "L": active
O
LCD drive signal output terminal
Power supply terminal (+3.2V)
O
System clock output terminal (5MHz)
I
System clock input terminal (5MHz)
Ground terminal
O
Not used
I
Not used
I
System reset signal input terminal "L": reset
O
Shift point terminal for oscillation frequency change
O
Not used
I
POWER key input terminal
I
CD lid open/close detection switch input terminal "L": CD lid is close
O
Not used
I
Interrupt request signal input terminal "L": active
I
CD interruption signal input terminal
Ground terminal
Not used
I
Key input terminal (A/D input)
I
Key input terminal (A/D input)
I
High voltage (+9V) detection signal input for battery check
I
REG-CHK detection signal input terminal
I
Middle voltage (+4.5V) detection input for battery check
"L": POWER key on
ZS-X3CP