d) When working outdoors with an electric tool
check to ensure that the tool is connected to the
electric supply by way of a ground fault circuit
interrupter (RCD) with a rating of max. 30 mA
(tripping current). Use of a ground fault circuit
interrupter reduces the risk of electric shock.
e) Use of a ground fault circuit interrupter (RCD
residual current device) with a maximum tripping
current of 30 mA is recommended.
f)
In case of an interruption in the electric supply:
Switch the power tool off and unplug the supply
cord. This will prevent accidental restarting when the
electric power returns.
5.3.4 Work area safety
a) Ensure that the workplace is well lit.
b) Ensure that the workplace is well ventilated. Ex-
posure to dust at a poorly ventilated workplace may
result in damage to the health.

6 Before use

6.1 Fitting and adjusting the side handle 2
CAUTION
Remove the depth gauge from the side handle in order
to avoid injury.
1.
Disconnect the supply cord plug from the power
outlet.

7 Operation

CAUTION
In accordance with the applications for which it is de-
signed, the power tool produces a high torque. Always
use the side handle and hold the power tool with both
hands. The user must be prepared for sudden sticking
and stalling of the insert tool.
CAUTION
Use clamps or a vice to hold the workpiece securely.
CAUTION
The collar at the front end of the gearing section is
not to be used as a gripping surface.
c) If the work involves breaking right through, take
the appropriate safety measures at the opposite
side. Parts breaking away could fall out and / or fall
down and injure other persons.
5.3.5 Personal protective equipment
The user and any other persons in the vicinity must
wear suitable eye protection, a hard hat, ear protec-
tion, protective gloves and breathing protection while
the tool is in use.
2.
Release the side handle clamping band by turning
the handle counterclockwise.
3.
Slide the side handle clamping band over the chuck
and onto the cylindrical section at the front end of
the power tool.
4.
Pivot the side handle into the desired position.
5.
Secure the side handle by turning the grip clockwise.
6.2 Unlocking the power tool
See section "Operation"
6.3 Use of extension cords and generators or
transformers
Please refer to section 2 "Description".
CAUTION
Check the insert tool for damage or uneven wear each
time before use.
7.1 Preparing for use
CAUTION
Wear protective gloves when changing insert tools as
the insert tools get hot during use.
7.1.1 Adjusting the depth gauge 3
1.
Release the side handle clamping band by turning
the handle counterclockwise.
2.
Pivot the side handle into the desired position.
3.
Attach the clamp with the depth gauge to the clamp-
ing band at the desired position.
4.
Release the screw at the depth gauge.