Cooling System Diagnostic Flowchart; Fig. 40 - Cooling System Diagnostics - Norcold NX61 Service Manual

Table of Contents

Advertisement

Cooling Unit - cont'd.

Cooling System Diagnostic Flowchart

Do not bypass or modify the refrigerator's controls or components
to diagnose the cooling system. Do not wire the heater(s) direct.
The heater is supplied power through a fused circuit.
Replace cooling unit.
Correct ventilation to meet
installation requirements
Correct heat input device to
meet specifications
Level refrigerator as outlined
in Owner's Manual and
specifications.
50
NX6 / NX8 / NXA Models
!
WARNING
Check cooling unit.
YES
Any signs of leak?
NO
NO
NO
.
YES
Check heat input.
NO
Heat input device
operating within
.
specification?
YES
NO
Refrigerator
operating leveled?
YES
Continued on following page

Fig. 40 - Cooling System Diagnostics

www.norcold.com/cda
!
Do not operate the refrigerator if
the cooling unit is leaking or a leak is
suspected.
YES
Reset Thermal Switch and
monitor carefully for
normal operation
Contact Customer Service
for further instructions
Refrigerator Service Manual
WARNING
YES
NO