Norcold N400 Installation Manual
Norcold N400 Installation Manual

Norcold N400 Installation Manual

Thetford n400: install guide
Hide thumbs Also See for N400:

Advertisement

For model N400 - a 4.5 cu. ft., 2-way or 3-way, refrigerator.
For model N500 - a 5.5 cu. ft., 2-way or 3-way, refrigerator.
For model N510 - a 5.5 cu. ft., 2-way or 3-way, refrigerator.
WARNING:
nance can cause injury or property damage. Refer to this manual.
For assistance or additional information, contact a qualified installer,
service agency, or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquid in
the vicinity of this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
WARNING:
DO NOT install this refrigerator in below
deck marine applications. Do not install this refrigerator in
fixed indoor cabin or other dwelling applications. This
refrigerator must use only NORCOLD designed and ap-
proved outside air intake and exhaust ventilation for correct
and safe operation. Any other ventilation could cause lethal
combustion exhaust fumes and/or explosive propane gas
fumes to be in the living area and/or to be below deck.
NORCOLD, Inc.
P.O. Box 4248
Sidney, OH 45365-4248

Installation Manual

Improper installation, adjustment, alteration, service or mainte-
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
English
French
Norcold Customer Support Dept.
Telephone: 800-543-1219
Web Site: www.norcold.com
Part No. 622265B (9-01)
Fax: 937-497-3183

Advertisement

Table of Contents
loading

Summary of Contents for Norcold N400

  • Page 1: Installation Manual

    For model N400 - a 4.5 cu. ft., 2-way or 3-way, refrigerator. For model N500 - a 5.5 cu. ft., 2-way or 3-way, refrigerator. For model N510 - a 5.5 cu. ft., 2-way or 3-way, refrigerator. WARNING: Improper installation, adjustment, alteration, service or mainte- nance can cause injury or property damage.
  • Page 2: Table Of Contents

    Change the travel latch position ... 6 Connect the Electrical Components ... 6 Connect the 120 volt AC supply ... 6 Connect the 12 volt DC supply (models N400.3 and ... N500.3) ... 7 Connect the 12 volt DC supply (model N510.3) ... 7 Connect the Propane Gas Components ...
  • Page 3: Certification And Code Requirements

    Certification and Code Requirements This refrigerator is certified under the latest edition of ANSI Z21.19 Standards by the American Gas Association for installa- tion in mobile homes or recreational vehicles and is approved by the Canadian Gas Association. The installation must obey these standards and this “Installation Manual”...
  • Page 4: Assemble The Enclosure

    3. Install the upper exhaust vent (see Art01283): - If you install the upper side exhaust vent: - For N400 models, make sure the distance [4] from the floor level to the top of the rough opening for the upper exhaust vent is at least 41 3/4 inches or poor cooling performance can occur.
  • Page 5: Install The Refrigerator

    NOTE: The decorative panels must be 3/16 inch or less in thickness. - For N400 models, make a decorative door panel [1] that is 31 inches high x 21 5/16 inches wide (See Art00977). - For N500 and N510 models, make a decorative door panel [1] that is 37 inches high x 21 5/16 inches wide (See Art00977).
  • Page 6: Change The Travel Latch Position

    - Tighten the screws. Change the travel latch position: This refrigerator allows you to put the travel latch either at the top of the door or at the bottom of the door regardless of the door swing direction (See Art01570 and Art01572).
  • Page 7: Connect The 12 Volt Dc Supply

    - Make sure the power cord does not touch the burner cover, the flue pipe, or any hot component that could damage the insulation of the power cord. Connect the 12 volt DC supply (models N400.3 and N500.3): As the distance from the vehicle battery to the refrigerator increases, the correct AWG wire size and fuse size also increases.
  • Page 8: Connect The Propane Gas Components

    Water Column), close the manual shutoff valve of the refrigerator before the test. Ignition Start Up Ignition - propane gas operation (N400 models): 1. Open the valve at the propane gas storage tank. 2. Turn the thermostat [1] to the 5 position.
  • Page 9: Ignition-Propane Gas Operation (N500 Models)

    - Turn the selector switch to the OFF position ( Ignition - propane gas operation (N510 models): Press the ON / OFF button to start the refrigerator in auto mode. - Push and hold the MODE button until the light bar flashes in the center display beside LP GAS.

This manual is also suitable for:

N500N510

Table of Contents