6.7 How to Test BDR91T Signal Strength

Honeywell 2-way RF
communications allows signal strength testing to verify BDR91T is positioned in the best possible location.
a.
Enter ST9520C Guided Binding Menu (ensure the slider is in the RUN position, then press and hold
seconds. The message 'BIND MENU' will show briefly, followed by the binding display).
b.
Navigate to the Signal Strength Test screen by pressing the
c.
Press the
button to activate the test. The ST9520C will show 'SIGNAL TST' and flash 'SS' on the display.
d.
Go to the BDR91T where the red light will flash several times quickly in succession, repeating every 5 seconds. The number of flashes in each
burst will be between 0 and 5, with 5 representing a strong signal and 0 a weak one.
e.
If the signal strength is less than 3, re-position the BDR91T within the local area +/- 1 or 2m to see if the signal strength improves.
f.
Signal Strength Test is cancelled by pressing the
button until the message 'SIGNAL TST OK?' appears on the display.
or
buttons on ST9520C or by moving the slider to exit the Guided Binding Menu.
19
,
and Zone 2 MODE buttons for 8