FAULT INDICATIONS

Blinking lights indicate a machine fault.
Blinking Lights
L3 and L7
L1–L8
L4 and L5
L1–L4

FAULT-TRACING PROGRAM

The functions of the electrical components can be tested by pressing S6 five times
then pressing one of the following:
S2 for inlet valve 2
S3 for inlet valve 1
S4 for combi-dispenser
S5 for heating element
S6 for the circulation pump
S7 for the outlet pump
S8 for fan motor and wax motor
Stop the fault-tracing program by pressing one of the program buttons for 3 seconds.
LINKS ON THE PROCESSOR BOARD
(for program variations)
These diodes should be cut for proper U.S.iInstallation:
Link 953:
Link USA:
Model D1996FI, SS, and HNDL
PROGRAMS
S = Pushbutton switch
Problem
Heating element
Overfill
Thermistor fault (heater control)
Water inlet
D1796 processor board layout
USA processor board layout
(DW 95FI)