Blue Defocus; White Balance - Hitachi 46F510 Service Manual

Hide thumbs Also See for 46F510:
Table of Contents

Advertisement

2.13 Blue Defocus adjustment
Adjustment Preparation
(1) Optical and electrical focus adjustment should
have been completed.
(2) The convergence adjustment should have been
completed.
(3) Set Video conditions to factory preset.
(4) Input the cross-hatch signal.
Adjustment procedure
(1) Turn the B Focus VR (Focus Pack) fully
clockwise.
(2) Adjust sticking out level of blue to specification
shown in table below, by turning the (B) FOCUS
VR counter clockwise.
UNEVENNESS SPECIFICATION: ±1cd/m 2
Defocus sticking out specification
Screen Size
46"
Condition: User controls are set to the initial set
positions (for shipment)
Measuring point-Screen center.
2.14 White balance adjustment
(1) Screen adjustment
(2) High light white balance.
(3) Low light white balance.
I
2
C data for High light white balance
Green : G DRIVE (HIGH) 3F (initial data)(Adjustable)
Red
: R DRIVE (HIGH) 3F (initial data)(Adjustable)
I
2
C data for Low light white balance
Green : G CUT OFF (HIGH) 7F (initial) (Fixed data)
Red
: R CUT OFF (HIGH) 7F (initial) (Adj. data)
Blue
: B CUT OFF (HIGH) 7F (initial) (Adj. data)
Adjustment Preparation
(1) Adjustment should start 20 min. or more after the TV
power is turned ON.
(2) CUT OFF ADJ. should be finished.
(3) VIDEO control : Contrast is MAX., Others are center.
(4) Color temp. : HIGH
(5) Signal:
*
Hight Light white Balance Adj.
White raster 0.715Vpp (w/o sync., termination
incidence : 75ohm.) 100IRE
*
Low Light white balance ADJ.
White raster 0.180Vpp (w/o sync., termination
incidence : 75ohm.) 25 IRE (The brightness
equal to 20cd/m
BACK TO ADJUSTMENTS
STICKING OUT OF BLUE
Blue sticking out
1.0mm
2
at screen center.
(6) BLUE defocus ADJ. should be finished.
(7) The vertical incident illumination on the screen
should be 20 Lux. or less.
(8) Picture Format is 16:9 Standard Mode.
(9
) Go into I
2
C service mode.
Table 1: White Balance Adjustment Signal
Screen Size
High light
[IRE]
[Vpp]
Low light
[IRE]
[Vpp]
Table 1 shows amplitude of White raster (without sync,
termination impedence: 75ohm).
Table 2: White Balance Adjustment Specification
Size Highlight
46"
10800K±0MPCD
(x=0.277 ± 0.004, y=0.284 ± 0.004) (x=0.277 ± 0.004, y=0.284 ± 0.004)
Adjustment Procedure
A. High Light W/B adjustment
(1) Receive signal for High Light white balance ADJ.
(2) Adjust white balance at center of screen, using R
DRV/ G DRV with remote control (see Table 2).
B. Low Light W/B adjustment
(1) Receive signal for Low Light white balance ADJ.
(2) Adjust white balance to center of screen, using R
CUT OFF/G CUT OFF/B CUT OFF with remote
control. Do not touch screen VRs (see Table 2).
(3) Take Green color as a reference color, then adjust
Low Light W/B by increasing other two colors CUT
OFF data. Do not change GREEN CUT OFF data.
CA-100 Probe should be set to a direction as shown
below.
Repeat A & B two or three times, until no adjustment
is needed (white balance tracking-GOOD). If W/B
tracking is not good, set all data (Both DRV and CUT
OFF) to inital data, and change reference color to
different color.
Note:
If Low Light adj. spec cannot be followed, apply
previous adj. spec. (adjust by eye.)
Set probe to above direction.
(Screw hole side should
be on the left side)
59
DP33KA/B
46"
100
0.715
25.0
0.175
Lowlight
10800K±0MPCD
Screw Hole
Flat Face
Screen
Top view of
CA-100 Probe

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp33kb46f500aDp33ka