Entering Characters; Osd Menu Settings; Camera Setup - Siemens CCDA1445 Installation Manual

¼” high speed dome camera
Hide thumbs Also See for CCDA1445:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Configuration

10.2.3 Entering characters

10.3 OSD menu settings

10.3.1 CAMERA SETUP

54
Building Technologies
Fire Safety & Security Products
To set e.g. preset titles or a password you have to enter characters.
1. Move the joystick to the right to enter the first character.
2. Move the joystick up or down to scroll through the characters.
3. Repeat the first two steps until you have entered all characters.
4. To cancel the entering and leave the option press <∞> (focus far).
5. To accept the entered characters press <O> (focus near).
The characters have been entered.
<FOCUS>
WB
ATW
<AE>
ZOOM LIMIT
X36
SHARPNESS
10
<LINE LOCK>
PRIVACY ZONE
P1 OFF
<ALARM ACTIONS>
ALARM RETURN
OFF
PICTURE FLIP
OFF
WD
OFF
Menu item
Option settings
<FOCUS>
See page [
WB (White Balance)
ATW (Auto tracking white): Automatically adjusts the white balance
for colour temperatures from 2000°K to 10000°K.
AUTO: Automatically adjusts the white balance for colour
temperatures from 3000°K to 7500°K.
ONE PUSH WB: This can be set using 72 "Pos" from the keyboard
/ matrix.
<AE>
See page [
ZOOM LIMIT
The zoom limit can be controlled for Wide angle or Telephoto angle.
The maximum optical zoom is X36; higher values are for electronic
zoom only.
SHARPNESS
The sharpness can be controlled from 0 to 15 (sharpest).
<LINE LOCK>
See page [
PRIVACY ZONE
8 privacy zones can be set ON/OFF.
See page [
<ALARM
See page [
ACTIONS>