9.2
Protocol select
Building Technologies
Fire Safety & Security Products
NOTICE
Please ensure to set the appropriate camera address and baud rate using the DIP
switches.
Make sure that the RS485 bus termination is only switched on at the last device
on the RS485 bus. On all other dome devices, the termination must be set to "off".
1
Switch for termination
OFF: RS485 bus termination off (default)
ON: RS485 bus termination on (only last device)
2
Protocol select (see table below)
Protocol
Pelco P
Pelco D
bit 2
OFF
ON
bit 3
OFF
OFF
bit 4
OFF
OFF
bit 5
OFF
OFF
Protocol
Ernitec
MOLYNX D
bit 2
OFF
OFF
bit 3
ON
OFF
bit 4
ON
OFF
bit 5
OFF
ON
Protocol select
Setting and controlling the dome camera
1
VCL
Vicon
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
SENSORMATIC
FIELDBUS
ON
ON
OFF
OFF
ON
OFF
OFF
ON
048_CCDA1445_A6V10257135_V1.0_en
2
Kalatel
OFF
OFF
ON
OFF
SIEMENS
ON
ON
ON
OFF
43
20.08.2009