DECK B
REC Bias Adjustment
Procedure:
INTRODUCTION
When set to the test mode performed in Tape Speed Adjustment,
when the tape is rewound after recording, the "REC memory mode"
which rewinds only the recorded portion and playback is set.
This "REC memory mode" is convenient for performing this
adjustment. During recording, the input signal FUNCTION will
automatically switch to VIDEO.
(If do not operation of stopped from recording complete, and rotate
of shuttle knob then rewind to recording start position.)
1. Press MD (VIDEO) button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B.
3. After press REC PAUSE/START button, press REC PAUSE/
START button, then recording start.
4. Mode: Record
MD/VIDEO (AUDIO) IN
1) 315 Hz
2) 10 kHz
AF OSC
600 Ω
attenuator
5. Mode: Playback
recorded
portion
set
CN301 (Pin 3 : L-CH)
6. Confirm playback the signal recorded in step 3 become
adjustable level as follows.
If these levels do not adjustable level, adjustment the RV304
(L-CH) and RV354 (R-CH) on the MAIN board to repeat steps
4 and 5.
Adjustable level: Playback output of 315 Hz to playback output
of 10 kHz: ±1.0 dB
Adjustment Location: MAIN board
DECK B
REC Level Adjustment
Procedure:
INTRODUCTION
When set to the test mode performed in Tape Speed Adjustment,
when the tape is rewound after recording, the "REC memory mode"
which rewinds only the recorded portion and playback is set.
This "REC memory mode" is convenient for performing this
adjustment. During recording, the input signal FUNCTION will
automatically switch to VIDEO.
(If do not operation of stopped from recording complete, and rotate
of shuttle knob then rewind to recording start position.)
1. Press MD (VIDEO) button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B.
3. After press REC PAUSE/START button, press REC PAUSE/
START button, then recording start.
18
50 mV (–23.8 dB)
blank tape
CN-123
set
level meter
+
(Pin 1 : R-CH)
4. Mode: Record
MD/VIDEO (AUDIO) IN
315 Hz, 50 mV (–23.8 dB)
AF OSC
600 Ω
attenuator
5. Mode: Playback
recorded
portion
set
CN301 (Pin 3 : L-CH)
6. Confirm playback the signal recorded in step 3 become
adjustable level as follows.
If these levels do not adjustable level, adjustment the RV301
(L-CH) and RV351 (R-CH) on the MAIN board to repeat steps
4 and 5.
Adjustable level:
CN301 PB level: 47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location: MAIN board
[MAIN BOARD] (Component Side)
PB LEVEL (R)
(A)
PB LEVEL (R)
REC LEVEL (R)
REC BIAS (L)
[LEAF SW BOARD]
(Conductor Side)
blank tape
CS-123
set
level meter
+
(Pin 1 : R-CH)
REC LEVEL (L)
PB LEVEL (L)
(A)
CN301
3
1
RV301
RV352
RV302
RV353
RV303
RV351
PB LEVEL (L)
(B)
RV304
RV354
REC BIAS (R)
TAPE SPEED
TAPE SPEED
(NORMAL)
(HIGH)
RV1001
RV1002