Areas and volumes can be added / subtracted in
GB
exactly the same manner.
F
Area
Press AREA/VOLUME - key {A, 3}. The corresponding
I
symbol {B, 5} appears in the display. The first side to
be measured flashes on the display. Take the two
E
measurements, the result will be displayed in the
P
main line.
NL
Volume
Press AREA/VOLUME - key {A, 3} twice. The corre-
DK
sponding symbol {B, 5} appears in the display. The
first distance to be measured flashes on the display.
S
When 3 measurements have been taken the result
N
will be displayed in the main line.
FIN
HISTORY
Pressing the HISTORY - key {A, 4} shows the last 19
J
displays in reverse order. Using the PLUS - key {A, 2}
and the MINUS - key {A, 7} allows to navigate in the
CN
historical storage.
ROK
In order to leave the history press either CLEAR - key
{A, 5}, ON/MEASURING - key {A, 1} or the AREA/
PL
VOLUME - key {A, 3}. Press and hold the HISTORY -
key {A, 4} until a beep, allows the user to take the
HR
selected result to carry on with calculations.
H
RUS
CZ

Appendix

GR
Appendix

Message Codes

All message codes will be displayed with either "InFo"
or "Error".
The following mistakes can be corrected:
InFo
Cause
204
Calculation error
252
Temperature too
high
253
Temperatur too low Warm up instrument
255
Receiver signal too
weak, measurement
time too long,
distance > 100 m
256
Received signal too
powerful
257
Wrong measure-
ment, ambient
brightness too high
260
Laser beam inter-
rupted
Error
Cause
Hardware error
4
Remedy
Repeat procedure
Cool down instrument
Use target plate
Use target plate
(grey side)
Use target plate
(brown side)
Repeat measurement
Remedy
Switch on/off the
device several times
and check if the
symbol still appears. If
so please call your
dealer for assistance.
Stanley TLM 210 1.0.0 gb