Greenstar Heatslave Series Horizontal - Worcester Greenstar Heatslave 12/18 Technical Information

Hide thumbs Also See for Greenstar Heatslave 12/18:
Table of Contents

Advertisement

Greenstar Heatslave series
horizontal fluing options (kitchen models)
Horizontal RS flue
Flue diameter
125mm
Maximum flue length
4,000mm
Standard flue kit
Comprises:
1 x terminal assembly
1 x internal finishing plate(s)
1 x external weather seal
1 x flue clamp
Part No. 7 716 190 031
Accessories
Worcester Part No.
125mm dia.
Flue Extension (1,000mm)
7 716 190 033
90º Bend
7 716 190 034
45º Bend
7 716 190 035
Horizontal Flue Kit
7 716 190 031
The following criteria should be noted when planning the
installation:
The flue system inclines 3º (53mm per metre) from the
appliance, to prevent condensation from dripping from
the flue terminal.
Because the appliance operates at high efficiency a
white plume of condensation will be emitted from the
terminal. Care must be taken when selecting the flue
terminal position.
The Greenstar Heatslave can be connected to a
conventional flue system or a multi-directional room sealed
balanced flue system.
Conventional flue
To convert the appliance to a conventional flue system the
vertical flue adaptor needs to be specified:
CF flue adaptor
Part No. 7 716 190 036
18
Option 1
Standard rear flue assembly
Maximum total straight flue length
125mm dia.
Kitchen models
140mm - 390mm
Flue components required
Flue Diameter
Description
Quantity
Worcester Part No.
Kitchen models
125mm
Standard Flue Kit
1
7 716 190 031
Option 2
Extended rear flue assembly
Maximum total straight flue length
125mm dia.
Kitchen models
4,000mm
Flue components required
Flue Diameter
Description
Quantity
Worcester Part No.
Kitchen models
125mm
Standard Flue Kit
1
7 716 190 031
125mm
Flue Extension
up to 4
7 716 190 033
Option 3
Extended rear flue assembly with a 90º bend
Maximum total straight flue length
125mm dia.
Kitchen models
3,000mm
Flue components required
Flue Diameter
Description
Quantity
Worcester Part No.
Kitchen models
125mm
Standard Flue Kit
1
7 716 190 031
125mm
Flue Extension
up to 3
7 716 190 033
125mm
90º Bend
1
7 716 190 034
Option 4
Extended rear flue assembly with 45º bends
Maximum total straight flue length
125mm dia.
Kitchen models
3,000mm
Flue components required
Flue Diameter
Description
Quantity
Worcester Part No.
Kitchen models
125mm
Standard Flue Kit
1
7 716 190 031
125mm
Flue Extension
up to 3
7 716 190 033
125mm
45º Bend (pair)
1
7 716 190 035
Option 5
Side flue extension*
Maximum total straight flue length
125mm dia.
Kitchen models
3,000mm
Flue components required
Flue Diameter
Description
Quantity
Worcester Part No.
Kitchen models
125mm
Standard Flue Kit
1
7 716 190 031
125mm
Flue Extension
up to 3
7 716 190 033
125mm
90º Bend
1
7 716 190 034
*For left hand flue options the expansion vessel within the boiler requires
removal and siting externally from the appliance.
Option 6
High level side discharge
Maximum total straight flue length
125mm dia.
Kitchen models
2,000mm
Flue components required
Flue Diameter
Description
Quantity
Worcester Part No.
Kitchen models
125mm
Standard Flue Kit
1
7 716 190 031
125mm
Flue Extension
2
7 716 190 033
125mm
90º Bend
2
7 716 190 034
x 2
19