12-2-13.Compressor wire missing error/rotation error

Indoor display
Outdoor display
1.Checklist :
1) Is the connection of cable for the compressor?
2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL)
3) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Restart after
power off.
Is the restart error occurred
YES
Isthe connection of compressor
wire is normal? (PBA and
Compressor)
YES
Is the restart error occurred
YES
Is the compressor body and
interphase resistance insulated?
NO
Exchangethe compressor
12-14
Outdoor error
Compressor wire missing error/rotation
error
again?
again?
NO
Terminatethe service
NO
Connectthe comp wire normally
NO
Terminate the service
YES
Exchange the Outdoor PBA

Hide quick links: