Filter Performance - Pressure Drop Inches W.c - Coleman FC9M060B12UP11 Technical Manual

Gas-fired condensing / high efficiency upflow modulating furnaces

Advertisement

BLOWER PERFORMANCE CFM - COOLING
Speed
MODELS
Tap
A
B
FC9M060B12UP11
FC9M080B12UP11
C
D
A
B
FC9M100C20UP11
C
D
A
FC9M080C16UP11
B
FC9M100C16UP11
C
D
A
B
FC9M120D20UP11
C
D
COOLING AIRFLOW WITH TWO SIDE RETURNS OR WITH BOTTOM AND ONE SIDE RETURN
MODELS
Speed
Input/
Tap
Airflow/Cabinet
A
B
FC9M100C20UP11
C
D
A
B
FC9M120D20UP11
C
D
NOTE: Low cool (W1) airflow is 65% of high cool airflow.
Blower speed adjustments should be done by moving the COOL jumper on the control
board. DO NOT move the motor wires to different positions on the furnace control board.
NOTES:
1. Airflow expressed in standard cubic feet per minute (CFM).
2. Return air is through side opposite motor (left side).
3. In order to stay within the velocity rating the filters, airflows above 1800 CFM require either return from two sides or one side plus bottom.
4. Motor voltage at 115 V.
FILTER PERFORMANCE
The airflow capacity data published in the "Blower Perfor-
mance" table listed above represents blower performance
WITHOUT filters. To determine the approximate blower per-
formance of the system, apply the filter drop value for the fil-
ter being used or select an appropriate value from the "Filter
Performance" table shown.
NOTE: The filter pressure drop values in the "Filter Perfor-
mance" table shown are typical values for the type of filter
listed and should only be used as a guideline. Actual pres-
sure drop ratings for each filter type vary between filter manu-
facturer.
Unitary Products Group
COOLING AIRFLOW WITH BOTTOM OR ONE SIDE RETURN
EXTERNAL STATIC PRESSURE, INCHES W.C. (kPa)
0.1
0.2
0.3
CFM
CFM
CFM
1650
1605
1570
1165
1185
1175
895
915
935
710
725
725
2300
2210
2120
1950
1900
1830
1610
1545
1490
1325
1270
1225
1960
1955
1925
1565
1560
1560
1230
1275
1285
930
945
965
2560
2485
2410
2090
2050
1990
1695
1675
1665
1175
1150
1135
EXTERNAL STATIC PRESSURE, INCHES W.C. (kPa)
0.1
0.2
0.3
CFM
CFM
CFM
2465
2380
2295
2085
2035
1960
1725
1625
1595
1420
1360
1310
2615
2535
2450
2055
2045
2015
1690
1650
1620
1345
1335
1335
0.4
0.5
0.6
CFM
CFM
CFM
1525
1465
1410
1165
1150
1140
940
940
920
725
720
700
2020
1930
1830
1755
1680
1595
1440
1390
1315
1175
1105
1045
1890
1830
1765
1575
1545
1530
1300
1310
1300
975
975
975
2320
2220
2135
1970
1885
1820
1615
1565
1510
1110
1085
1055
0.4
0.5
0.6
CFM
CFM
CFM
2195
2095
1995
1880
1800
1705
1540
1485
1405
1255
1180
1120
2385
2285
2175
1985
1932
1855
1600
1570
1525
1285
1250
1230

FILTER PERFORMANCE - PRESSURE DROP INCHES W.C.

Minimum
Airflow Range
Opening Size
2
CFM
in
0 - 750
230
751 - 1000
330
1001 - 1250
330
1251 - 1500
330
1501 - 1750
380
1751 - 2000
380
2001 & Above
463
259720-CTG-B-0108
0.7
0.8
0.9
CFM
CFM
CFM
1350
1275
1170
1100
1050
970
905
860
815
685
660
625
1715
1595
1480
1500
1390
1270
1230
1155
1050
990
905
890
1695
1615
1600
1475
1425
1365
1280
1245
1190
975
950
910
2035
1920
1785
1760
1675
1545
1460
1385
1285
1005
980
970
0.7
0.8
0.9
CFM
CFM
CFM
1875
1760
1620
1605
1485
1360
1315
1235
1125
1070
970
950
2075
1945
1825
1785
1730
1605
1470
1395
1300
1180
1115
1010
Filter Type
Washable
Disposable
Fibers
In W.C.
In W.C.
0.01
0.01
0.05
0.05
0.10
0.10
0.10
0.10
0.15
0.14
0.19
0.18
0.19
0.18
1.0
CFM
1060
875
750
560
1350
1155
920
790
1485
1260
1070
850
1650
1405
1140
845
1.0
CFM
1470
1235
995
845
1670
1470
1200
850
Pleated
In W.C.
0.15
0.20
0.20
0.25
0.30
0.30
0.30
9