Indoor Unit
SAP – K252A
Outdoor Unit
SAP – C252A
Power Source
Voltage rating
Capacity
Air circulation (High)
Moisture removal (High)
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor )
Air filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Operation sound
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant tube
diameter
Refrigerant tube kit / Accessories
Unit dimensions
Package dimensions
Weight
Shipping volume
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
BTU/h
m3 / h
Liters / h
W / W
Indoor / Outdoor
Horizontal
Vertical
Indoor – Hi / Me / Lo
dB-A
Outdoor – Hi
dB-A
Narrow tube
mm (in.)
Wide tube
mm (in.)
Height
Width
Depth
Height
Width
Depth
Net
Shipping
220 – 240 V Single phase 50 Hz
V
kW
V
A
W
%
A
Microprocessor / I.C. thermostat
Wireless remote control unit
1-hour OFF / 12-hour ON or OFF
3 and Auto / Auto (Hi, Lo)
g
m
Optional / Hanging wall bracket
Indoor Unit
mm
285
mm
995
mm
196
mm
276
mm
1,070
mm
363
kg
12.0
kg
15.0
m3
0.11
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
5
220 / 230 / 240
Cooling
7.00 / 7.00 / 7.00
23,900 / 23,900 / 23,900
840
3.3
198 to 264
13.1 / 13.1 / 13.4
2,730 / 2,730 / 2,800
95 / 91 / 87
2.56 / 2.56 / 2.50
67 / 70 / 73
Manual
Auto
Washable, Anti-Mold
Rotary (Hermetic)
R22 / 1,700
Capillary tube
43 / 41 / 39
55
Flare type
10
6.35 (1/4)
15.88 (5/8)
Outdoor Unit
630
810
275
704
953
396
59.0
62.0
0.25