Multi Variable Air Conditioners Floor and Ceiling Type Indoor Unit
● If the tightening torque is too great in tightening the flare nut, leakage will happen.
● The temperature of refrigerant circuit will be high ,please keep the interconnection away from the
copper tube.

3.7 Dial-up of Unit

The DC inverter unit of TOYOTOMI is provided with three dial-ups, i.e. address dial-up, capacity dial-up
and function dial-up. Adjust the function dial-up to set control, mode and function; Adjust the address dial-
up to set the corresponding relationship of indoor unit and wired controller; Adjust the capacity dial-up to set
capacity demand of indoor unit.
3.7.1 Function Dial-up
Caution!
Functional dial switch S7 is located on the mainboard of the indoor unit. It is operated when the user
need to change the default setting.
Dial-up Switch
1(S / R)
2(L / I)
3(M / S)
Setting of master / slave indoor unit
4(I / O)
5(L / H)
Setting of high / low static pressure fan
Functional description of function dial-up:
Dial-up switch 1 (S/R):
Setting of memory mode, including the standby mode and restoration mode. The standby mode refers
to that the previous parameters will be kept but the unit will not run automatically after the power supply
is resumed. This setting is factory defaulted (dial-up switch pulled to "ON" position). For example, if the
parameters of an indoor unit set before power shutdown are High Fan and 24 , the unit will be under standby
state after the power supply is resumed and after the unit is manually started, the parameters will remain as
High Fan and 24 . The restoration mode refers to that not only the previous parameters will be kept, but also
that the unit can start automatically after the power supply is resumed. But if the unit is under STOP state
before power shutdown, it will be also under STOP state after the power supply is resumed.
Dial-up switch 2 (L/I):
Setting of control mode, including wired control and remote control. The wired control mode refers to that
the indoor unit is controlled from wired controller (hand controller). This setting is factory defaulted (dial-up
switch pulled to "ON" position). When the setting is wired control mode, the function dial-up on S7 for "setting
of memory mode" and "setting of master / slave indoor unit" will be disabled. These two settings can be done
Functional dial switch S7
Functional Description:
Setting of memory mode
Setting of control mode
Setting of ambient temperature
acquisition point
Dial-up Setting
0 (ON Position)
Standby (S)
Wired control (L)
Master indoor unit (M)
Air inlet (I)
Low static pressure (L)
7
1
Restore (R)
Remote control (I)
Slave indoor unit (S)
Receiver (O)
High static(H)