Sanyo PLC-XE32 Service Manual page 35

Hide thumbs Also See for PLC-XE32:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
3
4 Sub Image Enable
6 Zoom Accelerator Enable
7 DZoom Reset by Keystone
8 Stability Count
9 Sensivity for Signal Lost
(HSYNC)
10 Sensivity for Signal Lost
(VSYNC)
11 Keystone Filter Center Value
Group
LampContorl
10
0 DIMMER_CTRL_LEVEL1
1 DIMMER_CTRL_LEVEL
 DIMMER_CTRL_LEVEL3
3 DIMMER_CTRL_LEVEL4
4 DIMMER_CTRL_LEVEL5
5 DIMMER_CTRL_LEVEL6
6 DIMMER_CTRL_LEVEL7
7 DIMMER_CTRL_LEVEL8
8 DIMMER_CTRL_LEVEL9
9 DIMMER_CTRL_LEVEL10
10 DIMMER_CTRL_LEVEL11
11 DIMMER_CTRL_LEVEL1
1 DIMMER_CTRL_LEVEL13
13 DIMMER_CTRL_LEVEL14
14 DIMMER_CTRL_LEVEL15
15 DIMMER_AVERAGE_POINT
16 DIMMER_AVERAGE_DATA
17 DIMMER_LEVEL_AUTO
18 DIMMER_LEVEL_NORMAL
19 DIMMER_LEVEL_ECO
0 Lamp check enable
1 VOLTAGE_LEVEL
Group
FAN Cntorol
50
0 FAN_TEMP_A_WARNING
1 FAN_TEMP_B_WARNING
 FAN_TEMP_C_WARNING
3 FAN_TEMP_B A_WARNING
4 FAN_TEMP_C A_WARNING
5 FAN__SPEED_MONI
6 FAN__SPEED_MONI
7 FAN_TEMP_A_MONI
8 FAN_TEMP_B_MONI
9 FAN_TEMP_C_MONI
10 Lamp Mode
11 Fan Ctrl Mode
Function
Count Value of V-missing
Only used this value for No Signal
Judgement(Hz)
Only used this value for No Signal
Judgement(Line)
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the Value
Luminance Level  Data for Dimmer:
Dim Level  at the less than the Value
Luminance Level 3 Data for Dimmer:
Dim Level 3 at the less than the Value
Luminance Level 4 Data for Dimmer:
Dim Level 4 at the less than the Value
Luminance Level 5 Data for Dimmer:
Dim Level 5 at the less than the Value
Luminance Level 6 Data for Dimmer:
Dim Level 6 at the less than the Value
Luminance Level 7 Data for Dimmer:
Dim Level 7 at the less than the Value
Luminance Level 8 Data for Dimmer:
Dim Level 8 at the less than the Value
Luminance Level 9 Data for Dimmer:
Dim Level 9 at the less than the Value
Luminance Level 10 Data for Dimmer:
Dim Level 10 at the less than the Value
Luminance Level 11 Data for Dimmer:
Dim Level 11 at the less than the Value
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the Value
Luminance Level 13 Data for Dimmer:
Dim Level 13 at the less than the Value
Luminance Level 14 Data for Dimmer:
Dim Level 14 at the less than the Value
Luminance Level 15 Data for Dimmer:
Dim Level 15 at the less than the Value
Luminance Data Avarage Point for
Mimmer
Luminance Data Avarage Value for
Dimmer
Current Dimmer Leverl
Normal Dimmer Level
Eco Dimmer Level
Lamp Voltage
Temperature A to judge the Temp.
Failure
Outside
Temperature B to judge the Temp.
Failure Panel
Temperature C to judge the Temp.
Failure Lamp
Temperature B-A to judge the Temp.
Failure Filter Cloggled
Temperature C-A to judge the Temp.
Failure Filter Cloggled
Fan Speed Monitor
Fan Speed Monitor
Temp. Sensor Monitor
Temp. Sensor Monitor
Temp. Sensor Monitor
High/Auto/Normal
Normal/Ceiling Switch
Initial
1
0
0
5
350
3
16
9
18
6
35
44
53
61
70
79
88
96
105
55
55
55
4
-
-
1
0
1
Nor-
Nor-
Ceiling-
Ceiling
mal-
mal
HiLand
HiLand
43
43
37
37
66
64
55
56
73
73
64
67
100
100
100
100
100
100
100
100
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
0
-35-
Range
Note
0:Disable (Service Adjustment Dsiable,
0 - 1
Used all the Center Values
1:Enable (Service Adjustment Enable)
0:Zoom Accelerator OFF,
0 - 1
1:Zoom Accelerator ON
No last memory
0:Enable (Normal), 1:Disable (Dzoo
is not cancelled even if Keystone is
0 - 1
cancelled)
No last memory
0 - 55
0 - 65535
0 - 55
0 - 30
0 - 55
Philips 00W
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 16
-
* Read only
-
* Read only
0 - 15
0 - 15
0: Lamp Failure Detection OFF (White
50% Back), 1 : ON (Blue 100% Back)
Unit: 8bit(Raw Data) * Read only
30-100
(Memorized)
30-100
(Memorized)
30-100
(Memorized)
(Memorized)
0-100
(Memorized)
0-100
-
* Read only
* Read only
* Read only
* Read only
* Read only
0-
0: High, 1: Auto, : Normal
0-1
0: Normal, 1: Ceiling

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents