Sharp AE-XM30GR Service Manual page 17

Muliti split type room air conditioners
Table of Contents

Advertisement

Thermistor
Outdoor temp. thermistor
Suction thermistor
Thermistor unit A (suction)
Thermistor unit B (suction)
Thermistor unit C (suction)
Thermistor unit D (suction)
2. How to distinguish the defective parts
1. When all rooms are not cooled
The cooling cycle is abnormal.
Check the pressure.
No.
Connector
TH3
CN8A
TH4
CN8A
TH6
CN8C
TH7
CN8C
TH8
CN8C
TH9
CN8C
Figure 3 Temperature properties of heatsink thermistor
500
Thermistor
Heatsink
400
To measure the resistance, first remove
the connector as shown at right.
300
200
100
0
-20
0
20
Temperature (ºC)
Are the timer lamps of the in-
door units in all rooms flashing ?
No
Press the OPERATION button
to start operating the air-condi-
tioner. (One-room operation ON)
(Set the cooling mode to 18
Yes
Is the compressor of the outdoor
unit operating ?
No
Are the timer lamps of the indoor
units in all rooms flashing ?
No
Check that the power between
the terminal board " N " and " 1 "
of the indoor unit is AC 230V,
50Hz.
Repair the wiring between the
units.
Color
Connector pin
Green
No. 5 to 6
Black
No. 7 to 8
Blue
No. 1 to 2
White
No. 3 to 4
Brown
No. 5 to 6
Yellow
No. 7 to 8
Color
Signal
Black
CN8B
Heatsink thermistor
TH5 (black)
25ºC resistance 50k
6.14k
12.3k
40
60
80
100
Yes
Yes
Check the failure symptom with
the failure diagnosis mode.
3 – 6
1
3
Tester
3.25k
(Check the failure with
the outdoor unit.)
A
TO

Advertisement

Table of Contents
loading

Table of Contents