Sanyo PLC-WTC500AL Service Manual page 64

Hide thumbs Also See for PLC-WTC500AL:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No.
Item
236
Lamp changer
0
Mirror Adjust Mode
1
Lamp Mode Lamp1
2
Lamp Mode Lamp2
10
Lamp1/Lamp2 Change Time
20
Lamp Timer On/Off
21
Lamp Timer Start
22
Lamp Timer Conut
23
Lamp Timer Interval
24
Lamp Timer Store
240
Flow Calibration
0
Flow Calibration Exe
1
Flow Calibration Error Log
2
Clog Check Enable
3
Air Inlet Check Enable
241
Flow Ideal Data
0
Flow Ideal Data 1
1
Flow Ideal Data 2
2
Flow Ideal Data 3
3
Flow Ideal Data 4
4
Flow Ideal Data 5
5
Flow Ideal Data 6
6
Flow Ideal Data 7
7
Flow Ideal Data 8
242
Flow Calib. Fan Duty
0
Flow Calib Fan Duty 1
1
Flow Calib Fan Duty 2
2
Flow Calib Fan Duty 3
3
Flow Calib Fan Duty 4
4
Flow Calib Fan Duty 5
5
Flow Calib Fan Duty 6
6
Flow Calib Fan Duty 7
7
Flow Calib Fan Duty 8
243
Flow Calib Effective Difference
0
Flow Calib Effective Diff 1
1
Flow Calib Effective Diff 2
2
Flow Calib Effective Diff 3
3
Flow Calib Effective Diff 4
4
Flow Calib Effective Diff 5
5
Flow Calib Effective Diff 6
6
Flow Calib Effective Diff 7
7
Flow Calib Effective Diff 8
244
Flow Clog Threshold
0
Flow Clog Threshold 1
1
Flow Clog Threshold 2
2
Flow Clog Threshold 3
3
Flow Clog Threshold 4
4
Flow Clog Threshold 5
5
Flow Clog Threshold 6
6
Flow Clog Threshold 7
Function
0: Normal, 1: Lamp1 Adj, 2: Lamp2 Adj.
Lamp1 Status
0: Lamp1 not selected (Select when value is set to 10.)
11: Lamp 1 selected
99: After lamp changed
Lamp2 Status
0: Lamp1 not selected (Select when value is set to 10.)
11: Lamp 1 selected
99: After lamp changed
Sets Lamp CHange Time (unit: hour)
Lamp Timer 0: On, 1: Off
Starting Time Set (h)
Timer Count Set (h)
Interval (h)
Timer Store
0: Timer Clear after Power Off
1: Memorized
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
Intake Error Detection vy Flow Sensor (0: Disable, 1: Enable)
(Value will be set after calibration)
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
(Not Memorized)
Flow Sensor Calibration Duty No.1 [%]
Flow Sensor Calibration Duty No.2 [%]
Flow Sensor Calibration Duty No.3 [%]
Flow Sensor Calibration Duty No.4 [%]
Flow Sensor Calibration Duty No.5 [%]
Flow Sensor Calibration Duty No.6 [%]
Flow Sensor Calibration Duty No.7 [%]
Flow Sensor Calibration Duty No.8 [%]
(Not Memorized)
Flow Sensor Calibration Range Diff No.1 [ADC]
Flow Sensor Calibration Range Diff No.2 [ADC]
Flow Sensor Calibration Range Diff No.3 [ADC]
Flow Sensor Calibration Range Diff No.4 [ADC]
Flow Sensor Calibration Range Diff No.5 [ADC]
Flow Sensor Calibration Range Diff No.6 [ADC]
Flow Sensor Calibration Range Diff No.7 [ADC]
Flow Sensor Calibration Range Diff No.8 [ADC]
(Not Memorized )
Flow Sensor Clogged Threshold No.1[ADC]
Flow Sensor Clogged Threshold No.2[ADC]
Flow Sensor Clogged Threshold No.3[ADC]
Flow Sensor Clogged Threshold No.4[ADC]
Flow Sensor Clogged Threshold No.5[ADC]
Flow Sensor Clogged Threshold No.6[ADC]
Flow Sensor Clogged Threshold No.7[ADC]
Range
0 - 2
-
-
0 - 255
0 - 2
0 - 24
1 - 255
0 - 1
0 - 1
-
0 - 1
0 - 1
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
-64-
Initial
Note
* Mirror adjustment
0
-
-
10
0
0
-
24
0
* Wind sensor
0
calibration.
255
Initial: 0 / Shipping: 1
Initial: 0 / Shipping: 1
242
275
309
335
359
378
428
447
31
36
42
48
54
60
80
100
250
250
250
250
250
250
250
250
36
57
75
92
108
121
153