6

LIMITED OPERATION BY GROUP CONTROL

NOTE
Group control: Operate air conditioners in more than one system in same time.
Header indoor unit: The representative unit during group control. Receive commands from wired remote
controller and transmit the commands to follower units.
(Header indoor unit is indoor unit that receives START/STOP signal from the wireless remote control.)
Follower indoor unit: Indoor units other than the Header unit are called follower unit.
A wired remote controller (separately available) is required for the group control.
▼ Example of group combination
Wired Remote controller
When using indoor unit in group control,
1. Hi POWER operation will not function.
When Hi POWER is transmitted from wireless remote controller the receiving sound will be heard from the
indoor unit and display on the wireless remote controller will also change. However, the indoor unit does not
operate Hi POWER operation. Restore the display on the wireless remote controller pushing Hi POWER
button.
2. COMFORT SLEEP
When COMFORT SLEEP is transmitted from wireless remote controller, the receiving sound will be heard
from the indoor unit and the display on the wireless remote controller will also be changed as same as Hi
POWER operation. However, the set temperature and the fan speed will not be automatically adjusted. Only
off timer function is activated.
3. Units other than the Header unit cannot be operated with remote controller and the
TEMPORARY operation.
When operating air conditioner with wireless remote controller transmission should be sent to the Header
unit.
Header and follower indoor units are decided through address setting upon installation. Follower unit will not
receive any signals from wireless remote controller.
Air conditioner will not work even if the
(Some Follower units may receive SWING and FIX, but these operations are performed only on the unit that
received the signal.)
(When wireless remote controller is used, only the Header unit receives SWING signal. If the SWING signal
is transmitted to follower unit, the sound to refuse receiving signal (3 beeps) is heard and the follower unit
does not receive the signal.
For FIX operation, both Header and follower unit perform the operation by itself.
When wired remote controller is used, airflow direction can be changed on each unit by selecting the indoor
unit.)
4. TIMER lamp lights up only on the Header unit.
When the timer is set with wired remote controller, even the TIMER lamp on the Header unit will not light up.
9-EN
Indoor
Indoor
Outdoor
Outdoor
Indoor
Outdoor
CAUTION
button on the follower unit is pressed.
– 9 –
Owner's Manual
Control line
Other connecting line