MDS-S9
NOTES ON HANDLING THE OPTICAL PICK-UP
BLOCK OR BASE UNIT
The laser diode in the optical pick-up block may suffer electro-
static break-down because of the potential difference generated
by the charged electrostatic load, etc. on clothing and the human
body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
JIG FOR CHECKING BD BOARD WAVEFORM
The special jig (J-2501-196-A) is useful for checking the waveform of the BD board. The names of terminals and the checking items to be
performed are shown as follows.
I+3V : For measuring IOP (Check the deterioration of the optical pick-up laser)
IOP : For measuring IOP (Check the deterioration of the optical pick-up laser)
GND : Ground
TE
: Tracking error signal (Traverse adjustment)
FE
: Focus error signal
VC
: Reference level for checking the signal
RF
: RF signal (Check jitter)
I+3V
GND
6
SECTION 1

SERVICING NOTES

IOP
TE
VC
FE
RF
NOTES ON LASER DIODE EMISSION CHECK
Never look into the laser diode emission from right above when
checking it for adjustment. It is feared that you will lose your sight.
I+3V
IOP
GND
TE
FE
VC
RF
CN105
1
I+3V
IOP
GND
for
TE
MDM-7A
FE
VC
RF