Data Lines; Handshake Lines; Nrfd (Not Ready For Data; Figure A-1. Gpib Cable Connector - National Instruments GPIB-100A User Manual

Bus extender
Table of Contents

Advertisement

Appendix A
Figure A-1 shows the arrangement of these signals on the GPIB cable connector.

Data Lines

The eight data lines, DIO1 through DIO8, carry both data and command messages. All
commands and most data use the 7-bit ASCII or ISO code set, in which case the eighth bit, DIO8,
is unused or used for parity.
Appendix E lists the GPIB command messages.

Handshake Lines

Three lines asynchronously control the transfer of message bytes among devices. The process is
called a three-wire interlocked handshake and it guarantees that message bytes on the data lines are
sent and received without transmission error.

NRFD (not ready for data)

NRFD indicates when a device is ready or not ready to receive a message byte. The line is driven
by all devices when receiving commands and by Listeners when receiving data messages.
© National Instruments Corporation
1
1 3
DIO1*
DIO5*
2
1 4
DIO6*
DIO2*
3
1 5
DIO3*
DIO7*
4
1 6
DIO4*
DIO8*
5
1 7
EOI*
REN*
6
1 8
DAV*
GND (TW PAIR W/DAV*)
7
1 9
GND (TW PAIR W/NRFD*)
NRFD*
8
2 0
NDAC*
GND (TW PAIR W/NDAC*)
9
2 1
IFC*
GND (TW PAIR W/IFC*)
1 0
2 2
SRQ*
GND (TW PAIR W/SRQ*)
1 1
2 3
ATN*
GND (TW PAIR W/ATN*)
1 2
2 4
SIGNAL GROUND
SHIELD

Figure A-1. GPIB Cable Connector