Timing Specifications

Name
Type
STB*
Input
IBF
Output
© National Instruments Corporation
2.
Using the following formula, calculate the largest possible load to
maintain a logic low level of 0.4 V and supply the maximum driving
current:
V = I × RL ⇒ RL = V/I
where:
V = 0.4 V
I = 46 µA + 10 µA
Therefore:
RL = 7.1 kΩ
This resistor value, 7.1 kΩ, provides a maximum of 0.4 V on the DIO line
at power up. You can substitute smaller resistor values to lower the voltage
or to provide a margin for V
smaller values draw more current, leaving less drive current for other
circuitry connected to this line. The 7.1 kΩ resistor reduces the amount of
logic high source current by 0.4 mA with a 2.8 V output.
6025E only
This section lists the timing specifications for handshaking with your
6025E PC<0..7> lines. The handshaking lines STB* and IBF synchronize
input transfers. The handshaking lines OBF* and ACK* synchronize
output transfers. Table 4-5 describes signals appearing in the handshaking
diagrams.

Table 4-5. Signal Names Used in Timing Diagrams

Strobe input—a low signal on this handshaking line loads data into
the input latch.
Input buffer full—a high signal on this handshaking line indicates
that data has been loaded into the input latch. A low signal indicates
the device is ready for more data. This is an input acknowledge
signal.
Voltage across RL
4.6 V across the 100 kΩ pull-up resistor
and 10 µA maximum leakage current
; 0.4 V/56 µA
variations and other factors. However,
cc
Description