3. Auto Calibration
Purpose: To bring the color adjustment of each
component into standard alignment.
Symptom of Misadjustment: The color adjustment
differs from component to component.
1. Input white raster signal (10%=10 IRE, 100%=100
IRE) from Component 1 Y jack.
2. Enter the service mode.
3. To enter the Auto Calibration adjustment mode,
press [6] button on the service remote control unit.
4. To start auto adjustment, press [CH o] button on
the service remote control unit.
- In the auto adjustment mode, "Calibration Check"
appears on the screen.
- Upon completion, "Calibration Check OK" and
"Push FCH UP key" appear on the screen.
- If the auto adjustment failure, "Calibration Check
NG" and "Push FCH UP key" appear on the
screen.
5. Unplug AC cord and plug it in AC outlet again to
reset then enter the service mode again.
4. Flicker Adjustment
*This adjustment is needed when reparing T-CON
CBA.
1. Enter the Service mode. (See page 5-1.)
2. Press [2] button on the remote control unit.
The following screen appears.
3. If Flicker Adjustment is not fit, the screen become
the following.
FLASH (Go and Off)
4. Turn the VR1 on the LCD Module so that flash
stops.
5-3
L4400EA