IMPORTANT SAFETY NOTICE Proper service and repair is important to the safe, reliable operation of all Funai Equipment. The service procedures recommended by Funai and described in this service manual are effective methods of performing service operations. Some of these service special tools should be used when and as recommended.
IMPORTANT SAFETY PRECAUTIONS Prior to shipment from the factory, our products are strictly inspected for recognized product safety and electrical codes of the countries in which they are to be sold. However, in order to maintain such compliance, it is equally important to implement the following precautions when a set is being serviced.
Page 5
3. Design Alteration Warning - Do not alter or add 7. Product Safety Notice - Some electrical and to the mechanical or electrical design of this TV mechanical parts have special safety-related receiver. Design alterations and additions, characteristics which are often not evident from including, but not limited to circuit modifications visual inspection, nor can the protection they give and the addition of items such as auxiliary audio...
Page 6
Precautions during Servicing A. Parts identified by the # symbol are critical for L. When connecting or disconnecting the internal safety. connectors, first, disconnect the AC plug from the Replace only with part number specified. AC supply outlet. B. In addition to safety, other parts and assemblies M.
Page 7
Safety Check after Servicing Examine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts and wires have been returned to original positions. Afterwards, perform the following tests and confirm the specified values in order to verify compliance with safety standards. 1.
STANDARD NOTES FOR SERVICING Circuit Board Indications How to Remove / Install Flat Pack-IC 1. The output pin of the 3 pin Regulator ICs is 1. Removal indicated as shown. With Hot-Air Flat Pack-IC Desoldering Machine: Top View Bottom View 1.
Page 9
3. The flat pack-IC on the CBA is affixed with glue, so With Soldering Iron: be careful not to break or damage the foil of each 1. Using desoldering braid, remove the solder from pin or the solder lands under the IC when all pins of the flat pack-IC.
Page 10
2. Installation With Iron Wire: 1. Using desoldering braid, remove the solder from 1. Using desoldering braid, remove the solder from all pins of the flat pack-IC. When you use solder the foil of each pin of the flat pack-IC on the CBA flux which is applied to all pins of the flat pack-IC, so you can install a replacement flat pack-IC more you can remove it easily.
Page 11
Instructions for Handling Semi- conductors Electrostatic breakdown of the semi-conductors may occur due to a potential difference caused by electrostatic charge during unpacking or repair work. 1. Ground for Human Body Be sure to wear a grounding band (1 MΩ) that is properly grounded to remove any static electricity that may be charged on the body.
CABINET DISASSEMBLY INSTRUCTIONS [ 6615LF4/STL1505 ] 1. Disassembly Flowchart Removal Step/ This flowchart indicates the disassembly steps for the Remove/*Unhook/ Loc. Part Fig. Unlock/Release/ cabinet parts, and the CBA in order to gain access to Note Unplug/Unclamp/ item(s) to be serviced. When reassembling, follow the Desolder steps in reverse order.
Page 13
[1] Rear Cabinet (S-1) (S-1) (S-1) (S-2) (S-1) Fig. D1 [7] Front Cabinet [6] Speaker (S-8) (S-6) [3] Main CBA (S-6) (S-7) [5] Function (S-6) (S-5) (S-6) (S-5) (S-6) (S-6) (S-5) (S-3) (S-8) [6] Speaker [4] LCD Main CBA & (S-6) Liquid Crystal Panel Unit (S-5)
Page 14
TV Cable Wiring Diagram Function CBA CLN104 LCD Main CBA & Liquid Crystal Panel Unit CN104 CN102B CN103B CN101B Main CBA CN113 CN402 CN103A CN102A CN101A CN403 CN801 CN802 To Speaker To Speaker LCD Main CBA & Liquid Crystal Panel Unit Fig.
Page 15
[ 6615LF ] 1. Disassembly Flowchart Removal Step/ This flowchart indicates the disassembly steps for the Remove/*Unhook/ Loc. Part Fig. Unlock/Release/ cabinet parts, and the CBA in order to gain access to Note Unplug/Unclamp/ item(s) to be serviced. When reassembling, follow the Desolder steps in reverse order.
Page 17
TV Cable Wiring Diagram Function CBA CLN104 LCD Main CBA & Liquid Crystal Panel Unit CN104 CLN105 IR Sensor CBA CN105 CN102B CN103B CN101B Main CBA CN113 CN402 CN103A CN102A CN101A CN403 CN801 CN802 To Speaker To Speaker LCD Main CBA & Liquid Crystal Panel Unit Fig.
ELECTRICAL ADJUSTMENT INSTRUCTIONS General Note: “CBA” is abbreviation for How to set up the service mode: “Circuit Board Assembly.” Service mode: Note: Electrical adjustments are required after 1. Use the service remote control unit. replacing circuit components and certain mechanical parts. It is important to perform 2.
Page 19
3. If Flicker Adjustment is not fit, the screen become Button Data the following. Item (on the service Value remote control) D2-BRT VCOM D2-CNT D2-CLR-R [MENU] → [5] D2-CLR-B D2-TNT FLASH (Go and Off) D2-SHR D3-BRT D3-CNT 4. Press [CH o / p] buttons on the remote control D3-CLR-R unit so that flash stops.
Page 20
The following adjustment normally are not 5. [RF/VIDEO1] attempted in the field. Only when replacing the When “x” value and “y” value are not within LCD Panel then adjust as a preparation. specification, adjust “DB (C/D1)” or “DR (C/D1)”. Refer to “1. Initial Setting.” 3.
HOW TO INITIALIZE THE LCD TELEVISION How to initialize the LCD television: 1. Turn the power on. (Use main power on the TV unit.) 2. To enter the service mode, press [POWER], [2], [7], [1], and [MUTE] buttons on the remote control unit in that order within 5 seconds.
SCHEMATIC DIAGRAMS / CBA'S AND TEST POINTS Standard Notes Many electrical and mechanical parts in this chassis have special characteristics. These characteristics often pass unnoticed and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts that have these special safety characteristics are identified in this manual and its supplements;...
Page 29
LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON THE FOLLOWING PAGES: 1. CAUTION: CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE_A,_V FUSE. ATTENTION: UTILISER UN FUSIBLE DE RECHANGE DE MÊME TYPE DE_A,_V. 2.
Page 31
Main 2/5 Schematic Diagram MAIN 2/5 Ref No. Position IC31 IC851 IC852 TRANSISTOR CONNECTOR CN113 L3100SCM2...
Page 32
Main 3/5 Schematic Diagram MAIN 3/5 Ref No. Position IC781 IC801 TRANSISTORS Q701 Q702 Q703 Q704 Q705 Q706 Q707 Q708 Q802 Q803 CONNECTORS CN801 CN802 CN103A L3100SCM3...
Page 33
Main 4/5 Schematic Diagram NOTE: CAUTION ! Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. The voltage for parts in hot circuit is measured using CAUTION ! : For continued protection against risk of fire, If Main Fuse (F601) is blown , check to see that all components in the power supply hot GND as a common terminal.
Page 36
IR Sensor Schematic Diagram ( 6615LF) L3108SCIR...
Page 37
LCD Main 1/2 Schematic Diagram LCD MAIN 1/2 Ref No. Position IC333 TRANSISTOR Q301 CONNECTORS CN104 CN105 CN111 CN211 CN311 CN102B L3100SCL1 8-10...
Page 38
LCD Main 2/2 Schematic Diagram LCD MAIN 2/2 Ref No. Position IC151 IC171 IC191 IC192 IC193 IC201 TRANSISTORS Q131 Q201 CONNECTORS CN112 CN312 CN101B CN103B 8-11 L3100SCL2...
Page 39
Main CBA Top View CAUTION ! Because a hot chassis ground is present in the power Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. supply circuit, an isolation transformer must be used. CAUTION ! : For continued protection against risk of fire, If Main Fuse (F601) is blown , check to see that all components in the power supply Also, in order to have the ability to increase the input...
Page 40
Main CBA Bottom View CAUTION ! Because a hot chassis ground is present in the power Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. supply circuit, an isolation transformer must be used. CAUTION ! : For continued protection against risk of fire, If Main Fuse (F601) is blown , check to see that all components in the power supply Also, in order to have the ability to increase the input...
Page 41
Function CBA Top View IR Sensor CBA Top & Bottom View (6615LF) BL3100F01011-2 BL3100F01011-3 Function CBA Bottom View BL3100F01011-2 8-14...
WAVEFORMS WF1 ~ WF12 = Waveforms to be observed at Waveform check points. (Shown in Schematic Diagram.) Input: NTSC Color Bar Signal (with 1kHz Audio Signal) CLKH STH1 S-VIDEO-C 1DIV: 1.0V 10 s 1DIV: 1.0V 10 s 1DIV: 200mV 20 s R392 R394 Pin 7 of CN103A...
EXPLODED VIEWS Cabinet [ 6615LF4/STL1505 ] SP802 CLN802 CLN801 Function CBA Main CBA SP801 L4 L10 LCD Main CBA & Liquid Crystal Panel Unit See Electrical Parts List for parts with this mark. AC601 11-1 L3100_05_08CEX...
Page 45
[ 6615LF ] Function CBA CLN802 SP802 CLN801 SP801 Main CBA IR Sensor CBA LCD Main CBA & Liquid Crystal Panel Unit See Electrical Parts List for parts with this mark. AC601 11-2 L3100_05_08CEX...
Page 46
Packing [ 6615LF4/STL1505 ] Some Ref. Numbers are not in sequence. Tape Tape Packing Tape Packing Tape Packing Tape 11-3 L3100PEX...
Page 47
[ 6615LF ] Some Ref. Numbers are not in sequence. Tape Tape Packing Tape Packing Tape Packing Tape 11-4 L3100PEX...
ELECTRICAL PARTS LIST PRODUCT SAFETY NOTE: Products marked with a Ref. No. Mark Description Part No. # have special characteristics important to safety. CHIP CERAMIC CAP .(1608) CH J CHD1JJ3CH102 1000pF/ 50V Before replacing any of these components, read CHIP CERAMIC CAP .(1608) B K 0.01µF/ CHD1JK30B103 carefully the product safety notice in this service manual.
Page 50
Ref. No. Mark Description Part No. Ref. No. Mark Description Part No. C505 CHIP CERAMIC CAP .(1608) B K 0.01µF/ CHD1JK30B103 C706 CHIP CERAMIC CAP .(1608) CH J CHD1JJ3CH102 1000pF/ 50V C506 CHIP CERAMIC CAP .(1608) B K 0.01µF/ CHD1JK30B103 C707 CHIP CERAMIC CAP .(1608) CH J CHD1JJ3CH102...
Page 51
Ref. No. Mark Description Part No. Ref. No. Mark Description Part No. C860 ELECTROLYTIC CAP . 10µF/50V M H7 CE1JMASSL100 D467 SWITCHING DIODE 1SS400 QD1Z001SS400 C861 ELECTROLYTIC CAP . 100µF/10V M H7 CE1AMASSL101 D468 SWITCHING DIODE 1SS400 QD1Z001SS400 C862 CHIP CERAMIC CAP .(1608) B K 0.01µF/ CHD1JK30B103 D469 SWITCHING DIODE 1SS400...
Page 52
Ref. No. Mark Description Part No. Ref. No. Mark Description Part No. D682 SWITCHING DIODE 1SS133(T-77) QDTZ001SS133 Q531 TRANSISTOR 2SC2120-O-TPE2 QQS002SC2120 D701 ZENER DIODE MTZJT-778.2B QDTB0MTZJ8R2 Q601# FET 2SK3869(Q) QFWZ2SK3869Q D702 ZENER DIODE MTZJT-778.2B QDTB0MTZJ8R2 Q603# TRANSISTOR 2SC2120-O-TPE2 QQS002SC2120 D703 ZENER DIODE MTZJT-778.2B QDTB0MTZJ8R2 Q633...
Page 55
FUNCTION CBA Ref. No. Mark Description Part No. FUNCTION CBA ---------- Consists of the following: CAPACITORS C101 ELECTROLYTIC CAP . 47µF/10V M H7 CE1AMASSL470 C103 CERAMIC CAP .(AX) B K 0.01µF/50V CA1J103TU011 RESISTORS CHIP RES.(1608) 1/10W J 10k Ω R101 RRXAJR5Z0103 CARBON RES.
Page 57
SUPPLEMENT SERVICE MANUAL Rating Label This service manual is for the 6615LF4 different LCD Module Assembly model, which is different from the previous 6615LF4 model. For 6615LF4 different LCD Module Assembly model, the letter (L3110UA) is printed on rating label on the back of the unit. Refer to the rating label illustration at right.
Page 58
SCHEMATIC DIAGRAMS / CBA'S AND TEST POINTS Standard Notes Many electrical and mechanical parts in this chassis have special characteristics. These characteristics often pass unnoticed and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts that have these special safety characteristics are identified in this manual and its supplements;...
Page 59
LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON THE FOLLOWING PAGES: 1. CAUTION: CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE_A,_V FUSE. ATTENTION: UTILISER UN FUSIBLE DE RECHANGE DE MÊME TYPE DE_A,_V. 2.
Page 61
LCD Main 1/2 Schematic Diagram LCD MAIN 1/2 Ref No. Position IC333 TRANSISTOR Q301 CONNECTORS CN104 CN105 CN111 CN211 CN311 CN102B L3110SCL1...
Page 62
LCD Main 2/2 Schematic Diagram LCD MAIN 2/2 Ref No. Position IC151 IC171 IC191 IC192 IC193 IC201 TRANSISTORS Q131 Q201 CONNECTORS CN112 CN312 CN101B CN103B L3110SCL2...
Page 63
Main CBA Top View CAUTION ! Because a hot chassis ground is present in the power Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. supply circuit, an isolation transformer must be used. CAUTION ! : For continued protection against risk of fire, If Main Fuse (F601) is blown , check to see that all components in the power supply Also, in order to have the ability to increase the input...
Page 64
Main CBA Bottom View CAUTION ! Because a hot chassis ground is present in the power Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. supply circuit, an isolation transformer must be used. CAUTION ! : For continued protection against risk of fire, Also, in order to have the ability to increase the input If Main Fuse (F601) is blown , check to see that all components in the power supply...
Page 65
Function CBA Top View BL3100F01013-2 Function CBA Bottom View BL3100F01013-2...
Page 66
Different parts from the previous model Ref. No. Description Part No. MECHANICAL PARTS RATING LABEL L3110UA ---------- ELECTRICAL PARTS LCD MAIN CBA & LIQUID CRYSTAL 1FSA10049 PANEL UNIT L3110PL...
Page 68
SUPPLEMENT SERVICE MANUAL Rating Label This service manual is for the 6615LF different LCD Module Assembly model, which is different from the previous 6615LF model. For 6615LF different LCD Module Assembly model, the letter (L3118UJ) is printed on rating L3118UJ label on the back of the unit.
Page 69
SCHEMATIC DIAGRAMS / CBA'S AND TEST POINTS Standard Notes Many electrical and mechanical parts in this chassis have special characteristics. These characteristics often pass unnoticed and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts that have these special safety characteristics are identified in this manual and its supplements;...
Page 70
LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON THE FOLLOWING PAGES: 1. CAUTION: CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE_A,_V FUSE. ATTENTION: UTILISER UN FUSIBLE DE RECHANGE DE MÊME TYPE DE_A,_V. 2.
Page 72
LCD Main 1/2 Schematic Diagram LCD MAIN 1/2 Ref No. Position IC333 TRANSISTOR Q301 CONNECTORS CN104 CN105 CN311 CN102B L3118SCL1...
Page 73
LCD Main 2/2 Schematic Diagram LCD MAIN 2/2 Ref No. Position IC151 IC171 IC191 IC192 IC193 IC201 TRANSISTORS Q131 Q201 CONNECTORS CN312 CN101B CN103B L3118SCL2...
Page 74
Main CBA Top View CAUTION ! Because a hot chassis ground is present in the power Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. supply circuit, an isolation transformer must be used. CAUTION ! : For continued protection against risk of fire, If Main Fuse (F601) is blown , check to see that all components in the power supply Also, in order to have the ability to increase the input...
Page 75
Main CBA Bottom View CAUTION ! Because a hot chassis ground is present in the power Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. supply circuit, an isolation transformer must be used. CAUTION ! : For continued protection against risk of fire, Also, in order to have the ability to increase the input If Main Fuse (F601) is blown , check to see that all components in the power supply...
Page 76
IR Sensor CBA Top & Bottom View Function CBA Top View BL3100F01013-3 BL3100F01013-2 Function CBA Bottom View BL3100F01013-2...
Page 77
Different parts from the previous model Ref. No. Description Part No. MECHANICAL PARTS RATING LABEL L3118UJ ---------- ELECTRICAL PARTS LCD MAIN CBA & LIQUID CRYSTAL 1FSA10049 PANEL UNIT L3118PL...