Adjustment
11.
Needle rise, hook clearance, needle height (final adjustm.) and needle guard
04.10
(On the PFAFF 1426 carry out this adjustment on both hooks)
5
11 - 12
Requirement
At stitch-length setting "4" and needle bar at 2 mm b.d.c.:
1. the hook point must be at "needle centre" with a hook-to-needle clearance of
0.05 to 0.1 mm;
2. the top of the needle eye must be 0.8 mm below the hook point;
3. and needle guard 8 must touch the needle just lightly.
4
2
8
6
7
0.05 - 0.1 mm
Fig. 11 - 10
Set stitch length "4" and loosen screws 1, 2, 3 and 4.
Set needle bar at 2 mm past b.d.c. and set hook point at "needle centre."
Set hook clearance according to Requirement 1 and tighten screws 1.
Turn shaft 5 so that there is a play of 0.1 mm in the coupling and tighten screws 2.
Making sure there is a slight play in the gear, move the collar up and tighten screws 3.