Indoor Unit Installation Drawings - Daikin FTXG25EV1BS Installation Manual

Inverter r410a split series
Hide thumbs Also See for FTXG25EV1BS:
Table of Contents

Advertisement

Indoor Unit Installation Drawings

Screws (Field supply)
The mounting plate should be installed
on a wall which can support the weight
of the indoor unit.
Secure the installation plate to the wall on
the side where the bottom frame and the
installation plate are secured to each other.
Front panel
50mm or more from walls
(on both sides)
Outlet vent panel
Air filters
B
Titanium Apatite
Photocatalytic Air-Purifying Filter
Install Titanium Apatite Photocatalytic
Air-Purifying Filter on air filter
Titanium Apatite
B
Photocatalytic
Air-Purifying Filter
Intelligent-Eye Sensor
CAUTION
1) Do not hit or violently push the Intelligent-eye sensor. This can lead to damage and malfunction.
2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor's detection area.
5
Installing and removing the indoor unit
A Mounting plate
1) Using the 2
2) Attach the tabs on the bottom frame firmly
1) Lift the marked parts on the bottom of the
Cushioning material
(do not remove)
2) Lift up the indoor unit and remove it from
30mm or more
from ceiling
Appearance of the indoor unit may
differ from some models.
See 4. How to open the indoor unit
service lid on p4 of the Installation
Tips for details.
Air filter
Attaching the indoor unit
marks on top of the indoor
unit, attach the
A
mounting plate hooks
onto the indoor unit.
onto the
A
mounting plate.
(2 on either side)
Removing the indoor unit
front grill, pull the front grill towards
yourself and disengage the tabs on the
bottom of the frame.
the top of the mounting plate.
Supporting plate
Caulk pipe hole gap
with putty.
C
Wireless
remote
controller
Screws
(Field supply)
Mounting
A
plate
Mounting
A
plate
Tab
Bottom frame
Marked
part (rear)
Supporting plate
Use when
opening the
front panel and
securing.
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe's cut line.
Before screwing the remote
controller holder to the wall, make
sure that control signals are
properly received by indoor unit.
D
Remote
controller
holder
IEnglish

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents