Page 1
DIGITAL VODEOCASSETTE RECORDER MSW-A2000/A2000P INSTALLATION MANUAL 1st Edition Serial No. 10001 and Higher: MSW-A2000 Serial No. 40001 and Higher: MSW-A2000P...
Page 2
4. Prevention against achieving hazardous condition due to uneven mechanical loading When this product is installed in a rack, please make sure that the rack does not achieve hazardous condition due to uneven mechanical loading. MSW-A2000 MSW-A2000P...
Page 3
Mettre au rebut les batteries usagées conformément aux instructions du fabricant. ADVARSEL! Lithiumbatteri-Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren. 1 (P) MSW-A2000 MSW-A2000P...
These manuals describe the maintenace and service information (service over- view, adjustments, board layouts, schematic diagrams, detailed parts list, etc.) for this unit. If these manuals are required, please contact your local Sony Sales Office/Service Center..Protocol Manual of Remote (9-pin) Connector (Available on request) This manual explains the protocol for controlling the VTR via the RS-422A (9-pin serial remote).
1-14. Reference System 1-15. Settings and Adjustment when External Equipment is Connected *Operation check If an error message appears on the time data display area, refer to the operation manual. (For more details, refer to the maintenance manual volume-1.) MSW-A2000 MSW-A2000P...
2 Plug holder (Brown) . Areas near heat sources. 3-613-640-01 . Dusty areas or areas subject to vibration. Please contact your local Sony Sales Office/Service . Areas with strong magnetic field. Center. . Areas with much electrical noise. AC inlet .
12.7 31.5 123.8 263.5 415.9 (38.5) 457.5 n Remove the feet when rack mounting. Unit : mm Dimensions when Rack-Mounting The MSW-A2000/A2000P allows the operation with the detached lower control panel unit. For details, refer to Section 1-12. MSW-A2000 MSW-A2000P...
(Refer to Section 1-3.) Foot Specified Rack Mount Kit RMM-130 (Optional accessory) PS4 x 20 When mounting this unit into Sony LMS (Library Manage- ment System) VTR console, it is necessary to modify the VTR console. Foot PS4 x 20 Keep these screws and the feet.
Page 11
(PSW4 x 16). B4 x 6 Tightening torque: 120 x 10 N . m {12.2 kgf . cm} PSW4 x 16 B4 x 6 4 x 16 Inner rail Rack angle PSW4 x 16 PSW4 x 16 Rack angle MSW-A2000 MSW-A2000P...
Page 12
14. Fully tighten the eight screws (B4 x 8) fixing the four rail brackets. Intermediate rail Tightening torque: 120 x 10 N . m {12.2 kgf . cm} Ball retainer Rack B4 x 8 Outer rail Rail bracket 50 to 55 mm Rack angle B4 x 8 MSW-A2000 MSW-A2000P...
Page 13
Be careful not to catch your finger or hand in rack 16. To fix the two outer rails to the rack, fully tighten the mount rail. eight loosely fitted hexagon socket head cap screws in step 12 using the L-shaped hexagon wrench. Stopper Intermediate rail Stopper Inner rail MSW-A2000 MSW-A2000P...
Page 14
22. Secure the unit to the rack with the two screws and two ornamental washers. Tightening torque: 120 x 10 N . m {12.2 kgf . cm} Ornamental washer RK5 x 14 RK5 x 14 Ornamental washer MSW-A2000 MSW-A2000P...
1-7. Matching Connectors and Cables When external cables are connected to the connector of this unit, the hardware listed below (or equiva- lents) must be used. Panel indication Matching connector (cable) Sony part No. Remarks AUDIO INPUT XLR 3P, MALE 1-508-084-00...
ISR (Interactive Status Reporting) 4 CONTROL PANEL 10P connector for an outside control panel connection only 4 VIDEO CONTROL D-SUB 15P connector for a TBC remote controller (BVR-50) connection 4 (OPTION) D-SUB 9P connector for an optional kit 1-10 MSW-A2000 MSW-A2000P...
Page 17
BNC x 2 Serial data transport interface (270 Mbit/s) in conformity to SMPTE 305M (SDTI) and SMPTE 322M (SDTI-CP) PHONE JM-60 stereo phone jack (Upper control panel) Analog audio up to _12 dBu (8 Z load), unbalanced 1-11 MSW-A2000 MSW-A2000P...
Page 18
EJECT STATUS ANALOG/DIGITAL ANALOG/DIGITAL STATUS REEL HUB REEL HUB STATUS REM2 SETTING DATA RESET REMOTE2 SETTING DATA RESET STATUS ALL REC INHIBIT ALL REC INHIBIT STATUS —— —— PLAY CLOSURE SW (PLAY) STOP CLOSURE SW (STOP) (Continue) 1-12 MSW-A2000 MSW-A2000P...
Page 19
TXD ; Transmitted Data (Output) DTR ; Data Terminal Ready (Output) PRIORITY SG ; Signal Ground DSR ; Data Set Ready (Input) RM TX(+) RTS ; Request to Send (Output) RM RX(_) CTS ; Clear to Send (Input) 1-13 MSW-A2000 MSW-A2000P...
S901 S1001 S900 S1000 S800 S700 S600 S500 S902 S1002 S801 S701 S601 S501 S400 S300 S200 S100 APR-52 Board (Side A) Refer to Section 1-16 for removing and reattaching the plug-in boards. < Top View > 1-15 MSW-A2000 MSW-A2000P...
Page 22
_20 dBm/600 Z (Factory setting) Audio output headroom settings Channel Ref. No. Output headroom and Switches state (\ \ \ \ \ : Knob position) S500 S600 S700 S800 20 dB 18 dB 16 dB 12 dB (Factory setting) 1-16 MSW-A2000 MSW-A2000P...
Page 23
When the variable level is selected, the level is adjusted with the PHONE level control knob. Channel Ref. No. Setting and Switch state (\ \ \ \ \ : Knob position) S901 Fixed Variable S1001 (Factory setting) 1-17 MSW-A2000 MSW-A2000P...
ON (CLOSE) : Displays extended menu of setup menu Never change the settings of the switches except above. SS-89 S101 S1501 S1502 SS-89 Board (Side A) Refer to Section 1-16 for removing and reattaching the plug-in boards. < Top View > 1-18 MSW-A2000 MSW-A2000P...
ITEM-117. Operation Setting of ITEM-117 Setting of PANEL enabled SELECT switch Lower control panel unit Front-side panel EXT or PARA FRONT side Rear-side panel REAR side Both panels PARA REAR side ITEM-117’s factory setting : EXT 1-19 MSW-A2000 MSW-A2000P...
Page 26
8. Take the connecting cable off the three cord holders on . Check the screw holes are visible from your side before the switch panel. tightening the screws. Cable holders Arm (left side) Cable Arm (right side) 1-20 MSW-A2000 MSW-A2000P...
Release lever tighten the screw. Back view Release lever Mode selection plate Screw Lower control panel unit Back view Mode selection plate Search dial Screw Search dial shaft Round hole The shaft is seen. Portion A 1-21 MSW-A2000 MSW-A2000P...
The STOP button blinks in the following either cases. When no reference signal is input to REF. VIDEO connector. When the reference video signal (REF.VIDEO input) is not synchronized with an input video signal selected by the video input selection. 1-22 MSW-A2000 MSW-A2000P...
To set the TIME CODE, open the P1 page (TCG/TCR SETTING) on the function screen. When Editing with an Editor (BVE-2000, etc.) Capable of the 1st Edit When MSW-A2000/A2000P is used by connecting to an editor, set as follows. Button...
1-15. Settings and Adjustment when External Equipment is Connected 1-15-3. System Phase Alignment An external reference video signal and analog composite signal must be input to MSW-A2000/A2000P after they are adjusted so that SC-H conforms to the specifications. When Connecting to a Digital Switcher Fundamentally, the system phase adjustment is not necessary.
4. Hold the eject levers and slowly pull the board out. DPR-155 SS-89 APR-52 AU-272 EQ-84 Pulling out Insertion The SDI-52 board is piggybacked onto the VPR-64 board. The AU-272 and EQ-84 boards should be removed together due to their structural feature. Locations of Plug-in Boards 1-25 MSW-A2000 MSW-A2000P...
Page 33
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.