operAting the Device
Unlock unit
Unlock channels
Lock channels
DMM14 MANUAL
8.11.4 Unlocking the complete unit
To unlock the complete unit, proceed as follows:
Step
Description
Press the SYSTEM CONTROL rotary knob at the same time
1
as the OUT rotary knob for longer than 3 seconds
8.11.5 Unlocking individual channels
To unlock individual channels, proceed as follows:
Step
Description
1
Lock the complete unit, to do this press the
SYSTEM CONTROL rotary knob at the same time as the OUT
rotary knob for longer than 3 seconds
2
Remove the lock on the required channel by pressing the
rotary knob for the required channel for longer than 3 seconds
8.11.6 Locking individual channels
To lock individual channels, the complete unit is locked first and the lock is
then removed for all channels that are not to be locked.
To lock individual channels, proceed as follows:
The rotary knob lock is removed.
The LOCKED LED is no longer lit.
The rotary knobs are in the basic LEVEL position.
The LOCKED LED is lit.
The original settings are stored.
Turning the rotary knob has no function.
All other rotary knobs are in LEVEL mode and can still be
operated.