A - Idle Control Switch — Use this switch to turn the idle
control feature on and off.
B - Run/Stop Switch — Set this switch to "Run" before
starting. Set switch to "Stop" to switch off engine.
C - 30 Amp, 2 Pole Circuit Breaker — The 120/240 Volt AC,
30A locking receptacle and the 120 Volt AC, 30A locking
receptacle is provided with a 2 pole circuit breaker to
protect the generator against electrical overload.
D - Main Circuit Breaker — The 120/240 Volt AC, 50A
receptacle is provided with a 2 pole circuit breaker to
protect the generator against electrical overload. This
circuit breaker also controls all AC receptacles.
E - 120/240 Volt AC, 50 Amp Receptacle — May be used to
supply electrical power for the operation of 120 and/or
240 Volt AC, 50 Amp, single phase, 60 Hz electrical
loads.
F - 120/240 Volt AC, 30 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical, lighting, appliance, tool and motor loads.
G - 120 Volt AC, 30 Amp Locking Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 30 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.
12
H - 120 Volt AC, 20 Amp Locking Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.
J - 120 Volt AC, 20 Amp, Duplex Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical,
lighting, appliance, tool and motor loads.
K - Identification Label — Provides model and serial
number of generator. Please have these readily available
if calling for assistance.
L - Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
M - Spark Arrester Muffler — Exhaust muffler lowers engine
noise and is equipped with a spark arrester screen.
N - Oil Filter — Filters engine oil to prolong engine life.
P - Circuit Breakers (AC) — The 120 Volt AC, 20A duplex
receptacle and the 120 Volt AC, 20A locking receptacle is
provided with "push to reset" circuit breakers to protect
the generator against electrical overload.
R - 12 Volt DC Receptacle — Use this receptacle with
battery charge cables to charge a 12 Volt battery. This
receptacle is protected by a 10 Amp auto reset circuit
breaker.