Dimplex WPM 2006 R Installation And Start-Up Instructions Manual page 54

Heat pump controller

Advertisement

Available languages

Available languages

6.1
E-16
System-specific parameters
Sets the desired hot water temperature
Sets the time programs for hot water blocks
Sets the times in which DHW preparation is
blocked
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is
lowered. Operations to lower the temperature
that exceed a week day are activated or
deactivated at the end of each day accordingly.
To carry out a thermal disinfection, the DHW is
heated up once to the desired temperature.
The heating period is terminated automatically
when the set temperature is reached or after 4
hours at the latest.
Sets the start time for the thermal disinfection
Sets the desired hot water temperature which is
to be reached during thermal disinfection
For each day of the week, it is possible to select
whether thermal disinfection is desired at the
set start time.
By setting Reset to "Yes", the maximum
calculated hot water temperatures in HP
operation are reset to a value of 65 °C. The
setting is automatically reset to "No".
Sets the preparation of swimming pool water
Sets whether swimming pool water preparation
is carried out with 1 or 2 compressors
Sets the time programs for blocking swimming
pool water preparation
Sets the time in which a swimming pool block is
to take place
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active for a swimming pool block.
Blocks that exceed a week day are activated or
deactivated at the end of each day accordingly.
The output of the auxiliary circulating pump can
be configured to allow parallel operation of the
auxiliary circulating pump and the heat pump's
compressor. Configuration is possible for
heating, DHW preparation and swimming pool
water preparation. The antifreeze functions are
ensured.
Setting range
Display
30 °C
Domestic hot water
... 45 °C ...
Sensor
85 °C
Domestic hot water
00:00
Domestic hot water
...
23:59
N
Heating circuit 3
T1
T2
Y
Domestic hot water
Sensor
Bivalent or flange
heater
00:00
Domestic hot water
...
Sensor
23:59
Bivalent or flange
heater
60 °C
Domestic hot water
... 65 °C ...
Sensor
85 °C
Bivalent or flange
heater
N
Domestic hot water
Y
Sensor
Bivalent or flange
heater
No
Domestic hot water
Yes
Sensor
Swimming pool
1 Compressor
Swimming pool
2 Compressors
2 Compressors
Nonreversible HP
Swimming pool
00:00
Swimming pool
...
23:59
N
Swimming pool
T1
T2
Y
At all times