Top Exit Vertical Termination - Napoleon GDS28N Installation And Operating Instructions Manual

Ng and propane
Table of Contents

Advertisement

Available languages

Available languages

3.9

TOP EXIT VERTICAL TERMINATION

Simple venting configurations.
For vent configurations requiring one or more 90° elbows the following formulas apply:
Formula 1: H
< V
T
T
Formula 2: H
+ V
T
T
Example:
V
= 5 FT (1.5m)
1
V
= 6 FT (1.8m)
2
V
= 10 FT (3.1m)
3
V
= V
+ V
+ V
= 5FT (1.5m) + 6FT (1.8m) + 10FT (3.1m) = 21FT (6.4m)
T
1
2
3
H
= 8 FT (2.4m)
1
H
= 2.5 FT (0.8m)
2
H
= H
+ H
= 8FT (2.4m) + 2.5FT (0.8m) = 10.5 FT (3.2m)
R
1
2
H
= .03 (four 90° elbows - 90°)
O
= .03 (360° - 90°) = 8.1 FT (2.5m)
H
= H
+ H
= 10.5FT (3.2m) + 8.1FT (2.5m) = 18.6FT (5.7m)
T
R
O
H
+ V
= 18.6FT (5.7m) + 21FT (6.4m) = 39.6FT (12.1m)
T
T
Formula 1:
H
18.6FT (5.7m) < 21FT (6.4m)
Formula 2:
H
39.6FT (12.1m) < 40FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
< 40 feet (12.2m)
< V
T
T
+ V
< 40 FT (12.19m)
T
T
(H
) < (V
)
T
T
See graph to determine the required vertical rise V
required horizontal run H
40 (12.2)
30 (9.1)
REQUIRED
VERTICAL
RISE IN FEET
20 (6.1)
(METERS) V
T
10 (3.1)
3 (0.9)
0
HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H
The shaded area within the lines represents acceptable
values for H
90°
V
1
.
T
5
10
15
20
(1.5)
(3.1)
(4.6)
(6.1)
and V
T
T
90°
H
2
V
H
2
1
90°
18.1A
W415-1426 / 12.23.14
17
EN
for the
T
T
V
3
90°

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs28nGds28pGs28p

Table of Contents