Administrator Login Failure

If you are unable to perform an Administrator login (because the Username and
Password information has become corrupted, or you have forgotten it, for
example), you can clear the login information with the following procedure:
1. Power off the switch and remove its housing.
2. Short the jumper labeled Restore Default Password at the right front of the
switch's main board.
3. Power on the switch.
4. Wait a few seconds; power off the switch; and remove the jumper cap.
5. Replace the switch's housing and start it back up.
6. After you start back up, the OSD login function acts exactly the way it did
the first time the switch was run (see page 23), and you can reset
passwords for the Administrators and Users.