OPERATING HEATER
Continued
6. With control knob pressed in, push down
and release ignitor button. This will light
pilot. The pilot is attached to the front of
the burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 20. Also contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
If control knob does not pop up when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety interlock
system. Wait one (1) minute before lighting
pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between 1 and 5.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Figure 22 - Pilot (actual pilot may vary)
113680-01B
Thermocouple
Ignitor Electrode
Pilot Burner
www.desatech.com
17