Desa 125-RN Owner's Manual

Desa owner's manual gas-fired infrared construction heater 125-r, 125-rn
Hide thumbs Also See for 125-RN:
Table of Contents

Advertisement

Available languages

Available languages

GAS-FIRED INFRARED CONSTRUCTION HEATER
OWNER'S MANUAL
MODELS 125-R AND 125-RN
IMPORTANT: Read and understand this manual before
assembling, starting or servicing heater. Improper use
of heater can cause serious injury. Keep this manual for
future reference.
GENERAL HAZARD WARNING:
Failure to comply with the precautions and instructions
provided with this heater, can result in death, serious
bodily injury and property loss or damage from hazards
of fire, explosion, burn, asphyxiation, carbon monoxide
poisoning and/or electrical shock.
Only persons who can understand and follow the in-
structions should use or service this heater.
If you need assistance or heater information such as an in-
structions manual, labels, etc. contact the manufacturer.
Save this manual for future reference.
For more information, visit www.desatech.com

Advertisement

Table of Contents
loading

Summary of Contents for Desa 125-RN

  • Page 1 GAS-FIRED INFRARED CONSTRUCTION HEATER OWNER’S MANUAL MODELS 125-R AND 125-RN IMPORTANT: Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. GENERAL HAZARD WARNING: Failure to comply with the precautions and instructions...
  • Page 2: Table Of Contents

    Safety Information ... 2 Product Identification ... 3 Unpacking ... 3 Theory of Operation ... 3 Gas Supply ... 4 Ventilation ... 4 Installation Instructions ... 4 Locating Heater ... 5 Piping ... 5 SAFETY INFORMATION WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproduc-...
  • Page 3: Safety Information

    SAFETY INFORMATION Continued 7. Keep appliance area clear and free from com- bustible materials, gasoline, paint thinner and other flammable vapors and liquids. Dust is combustible. Do not use heater in areas with high dust content. 8. Minimum heater clearances from com- bustibles: Sides 1.54 m (5 ft)
  • Page 4: Gas Supply

    Less gas is vaporized at lower temperatures. Your local propane gas dealer will help you select the proper supply system. NATURAL GAS MODEL 125-RN ONLY The user must furnish the natural gas supply and the connections to the heater. Regulate the natural gas supply down from a mini- mum 7"...
  • Page 5: Locating Heater

    Consult with your local propane/LP dealer for details concern- ing proper equipment and installation. FOR MODEL 125-RN (FOR USE WITH NATURAL GAS ONLY) Piping must be clean and free from scale or burrs. Install regulator supplied with heater. Connect with 1/2"...
  • Page 6: Operating Instructions

    OPERATING INSTRUCTIONS WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life. CAUTION: This appliance is hot during normal operation, avoid physical contact. CAUTION: Do not place clothing or other combustible materials on this appliance.
  • Page 7: Maintenance

    Supply Pressure To Regulator (for input adjustment) Maximum Minimum Manifold Pressure Weight Heater Shipping Size - L x W x H Min Temperature Natural Gas Model 125-RN Rating Fuel Fuel Consumption per Hour Manifold Pressure 1.5 kPa (6 inches W.C.) Weight Heater Shipping...
  • Page 8: Troubleshooting

    WARNING: Never attempt to service heater while it is connected to propane supply, operating or hot. Severe burns can occur. SYMPTOM Burner fails to light Pilot lights but goes out when automatic control valve button is released Burn rate is low TROUBLESHOOTING POSSIBLE CAUSE 1.
  • Page 9: Replacement Parts

    In most cases, we will ask you to return the part to the factory. PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Productsʼ at 1-866-672-6040 or DESA Industries at 1-905-826-8010.. When calling DESA, have ready: •...
  • Page 10: Illustrated Parts Breakdown

    ILLUSTRATED PARTS BREAKDOWN MODELS 125-R AND 125-RN www.desatech.com 114248-01B...
  • Page 11: Parts List

    114208-01 114209-01 114212-01 114213-01 114216-01 114241-01 114242-01 114245-01 114246-01 113985-02 115297-01 ** Not a field replaceable part 114248-01B PARTS LIST 125-RN DESCRIPTION 104119-01 Manual Control Valve 114049-01 Filter/Diffuser 114148-01 Pilot Orifice 114121-01 Thermocouple 114128-01 Pilot Burner _____ Hose/Regulator Assembly 103406-03...
  • Page 12: Warranty And Repair Service

    Serial No. Date of Purchase DESA warrants this product and any parts thereof, to be free from defects in materials and workmanship for one (1) year from the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail purchaser, when proof of purchase is provided.
  • Page 13 APPAREIL DE CHAUFFAGE DE CHANTIER AU GAZ À INFRAROUGE MANUEL D’UTILISATION MODÈLES 125-R ET 125-RN IMPORTANT : Lisez et comprenez ce manuel avant d’assembler, d’allumer ou de réparer l’appareil de chauffage. Une mauvaise utilisation de l’appareil de chauffage peut causer des blessures graves.
  • Page 14 Information relative à la sécurité ... 2 Identification du produit ... 3 Déballage ... 3 Théorie de fonctionnement ... 3 Alimentation en gaz ... 4 Ventilation ... 4 Instructions pour l’installation ... 4 Placement de l’appareil de chauffage ... 5 Tuyauterie ...
  • Page 15: Information Relative Àla Sécurité

    INFORMATION RELATIVE À LA SÉCURITÉ 4. Assurez une ventilation suffisante. Avant dʼutiliser le radiateur, aménagez une prise dʼair frais de lʼextérieur dʼau moins 0,35 m 5. Nʼutilisez pas lʼappareil de chauffage dans un édifice habité ou dans des endroits où lʼon vit et dort. 6.
  • Page 16: Alimentation En Gaz

    Moins de gaz se vaporise à basse température. Votre fournisseur de gaz propane local vous aidera à choisir le système dʼalimentation qui convient. MODÈLE 125-RN AU GAZ NATUREL SEULEMENT Lʼutilisateur doit fournir lʼalimentation en gaz et les raccordements au radiateur.
  • Page 17: Placement De L'appareil De Chauffage

    GPL pour plus de renseignements sur le matériel approprié et son installation. POUR LE MODÈLE 125-RN (UTILISATION AVEC GAZ NATUREL SEULEMENT) La tuyauterie doit être propre, libre de calamine et de bavures.
  • Page 18: Notice D'utilisation

    NOTICE D’UTILISATION AVERTISSEMENT : si vous ne suivez pas ces instructions à la lettre, il pourrait se produire un incendie ou une explosion, causant des dégâts matériels, des blessu- res ou même la mort. ATTENTION : cet appareil de- vient chaud en fonctionnement nor- mal;...
  • Page 19: Entretien

    Pression au collecteur (CE) Poids Radiateur Expédition Dimensions - L x P x H 40,6 x 45,7 x 109,2 cm Température minimale -29 °C (-20 °F) Modèle 125-RN au gaz naturel Rendement Combustible Consommation de carburant à lʼheure Pression au collecteur (CE)
  • Page 20: Dépannage

    AVERTISSEMENT : ne tentez jamais de réparer l’appareil de chauf- fage pendant qu’il est branché au réservoir de propane, qu’il fonctionne ou qu’il est chaud. Des brûlures graves peuvent en résulter. SYMPTÔME Le brûleur ne sʼallume pas La veilleuse sʼallume, mais elle sʼéteint dès que le bouton de la vanne de contrôle automatique est relâché...
  • Page 21: Pièces De Rechange

    DESA dʼorigine, communiquez avec DESA Heating Products au 1-866-672-6040 ou DESA Industries au 1-905-826-8010. Lorsque vous appelez DESA, ayez sous la main : • votre nom et votre adresse • le modèle et le numéro de série de lʼappareil de chauffage •...
  • Page 22: Vue Détaillée Et Liste Des Pièces

    VUE DÉTAILLÉE DES PIÈCES MODÈLES 125-R ET 125-RN www.desatech.com 114248-01B...
  • Page 23 114212-01 114213-01 114216-01 114241-01 114242-01 114245-01 114246-01 113985-02 115297-01 ** Remplacement à l’usine seulement. 114248-01B LISTE DES PIÈCES 125-RN DESCRIPTION 104119-01 Robinet de contrôle manuel 114049-01 Filtre-diffuseur 114148-01 Orifice de la veilleuse 114121-01 Thermocouple 114128-01 Brûleur de la veilleuse _____ Assemblage de tuyau et de détendeur...
  • Page 24: Service De Garantie Et De Réparation

    Date de l’achat DESA Heating Products garantit ce produit et toutes les pièces quʼil contient contre tout défaut de matériau et de fabrication pour un (1) an à partir de la date dʼachat originale lorsque utilisé et entretenu selon les instructions. Cette garantie ne protège que lʼacheteur au détail dʼorigine lorsquʼune preuve dʼachat est fournie.

This manual is also suitable for:

125-r

Table of Contents